2007
DOI: 10.1016/j.jbiomech.2006.03.009
|View full text |Cite
|
Sign up to set email alerts
|

Posterior and anterior components of force during bite loading

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
19
0
2

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 21 publications
(25 citation statements)
references
References 34 publications
1
19
0
2
Order By: Relevance
“…Our study population showed considerable variability in PAF size. Our finding, that the PAF area increases in the anteroposterior direction, can be related to the high magnitude of force exerted on the posterior teeth during mastication and agrees with previous results .…”
Section: Discussionsupporting
confidence: 93%
“…Our study population showed considerable variability in PAF size. Our finding, that the PAF area increases in the anteroposterior direction, can be related to the high magnitude of force exerted on the posterior teeth during mastication and agrees with previous results .…”
Section: Discussionsupporting
confidence: 93%
“…The tightness of dental contact point (TDCP) device measures the force needed to insert a thin metal strip at the contact point (CP) between adjacent teeth (29, 30). The insertion forces the teeth to tip within PDL, and the measured force provides information regarding the immediate tooth movement as a solid material within the PDL tissue.…”
Section: Introductionmentioning
confidence: 99%
“…Tightness of dental contact point measurements were taken according to a previous protocol (5) using the TDCP device (Fig. 1) (29, 30). In short, this device, by using a tailor‐made load cell incorporated in the device handle, measures the force needed to insert a metal strip with a predetermined thickness through the contact point of two adjacent teeth.…”
mentioning
confidence: 99%
“…This study was conducted by inserting a 0.1 mm metal spacer between the two mandibular premolars with functioning interproximal contacts at the level of the contact point (CP) and the change over time of the CP tightness after removal of the spacer was measured with a tightness of dental contact point (TDCP) device (Vardimon et al, 2001(Vardimon et al, , 2003(Vardimon et al, , 2007. The spacer was placed for 1 min, and after removal, sequential measurements of contact point tightness were taken using repetitive insertions of the TDCP device (0.05 mm strip thickness) at the same interproximal CP.…”
Section: Mathematical Model Developmentmentioning
confidence: 99%