2000
DOI: 10.3109/00206090009073049
|View full text |Cite
|
Sign up to set email alerts
|

Post-operative Stapedius Reflex Tests with Simultaneous Loudness Scaling in Patients Supplied with Cochlear Implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
40
0
7

Year Published

2004
2004
2016
2016

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(50 citation statements)
references
References 9 publications
3
40
0
7
Order By: Relevance
“…It employs the Continuous Interleaved Sampling (CIS) strategy as developed by Wilson et al (1995), with a pulse rate typically set to about 1500 pulses per second on each electrode. Recordings of SRs using this device have been reported by Stephan and Welzl-Muller (2000) in a small group of six subjects, one using the COMBI 40+ implant and five using the original eight-channel COMBI 40 device. These authors examined loudness growth functions of behavioural percepts and SR magnitude and demonstrated a strong correlation between the two measures.…”
Section: Introductionmentioning
confidence: 99%
“…It employs the Continuous Interleaved Sampling (CIS) strategy as developed by Wilson et al (1995), with a pulse rate typically set to about 1500 pulses per second on each electrode. Recordings of SRs using this device have been reported by Stephan and Welzl-Muller (2000) in a small group of six subjects, one using the COMBI 40+ implant and five using the original eight-channel COMBI 40 device. These authors examined loudness growth functions of behavioural percepts and SR magnitude and demonstrated a strong correlation between the two measures.…”
Section: Introductionmentioning
confidence: 99%
“…Although a very good correlation between ESRT and C-values used in programming has been reported by Stephan and Welzl-Müller [2000] in six patients with Medel implants (r = 0.92), we did not demonstrate similar findings in our study [Müller-Deile, 2009] of 18 postlingually deafened adults who were experienced Advanced Bionics Comparison of the speech intelligibility in patients fitted with psychoacoustic procedures for T-and C-values (traditional, n = 160 patients) and patients fitted with the TAutoNRT-based procedure (NRT, n = 111). Freiburg monosyllables in quiet at 70 and 60 dBSPL.…”
Section: Results For Implanted Malformation Cases CImentioning
confidence: 99%
“…Procedures: The thresholds of the stapedius reflex excited via electrical stimulation of the auditory nerve (ESRT) [Stephan and Welzl-Müller, 2000], as well as the thresholds of electrically evoked auditory brainstem responses [Van den Borne et al, 1994] and electrically evoked compound action potentials (ECAP) [Cafarelli Dees et al, 2005] have been reported to be estimators for T-and C-levels. The following describes some of the research and clinical application of these methods in more detail.…”
Section: Results For Implanted Malformation Cases CImentioning
confidence: 99%
“…Stephan and Welzl-Müller [7] investigated the eSR threshold and the MCL recorded in units of current in 5 adult users of the Med-El Combi 40 system. A high r value of 0.92 was found, pointing to the usefulness of the eSR threshold in determining MCL levels.…”
Section: Discussionmentioning
confidence: 99%