ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING: FROM THEORY TO APPLICATIONS (SERIES 2): Proceedings of the International Con 2019
DOI: 10.1063/1.5133931
|View full text |Cite
|
Sign up to set email alerts
|

Post-fault tolerant of symmetrical six-phase induction machine under open circuit fault with single and two isolated neutral points using graphical user interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…For multiphase machines, analysis is usually performed based on the Vector Space Decomposition (VSD) model [33], where the machine variables can be decoupled into fluxand-torque producing α-β components, non-flux-and-torque producing x-y components and zero sequence 0 1 -0 2 components. The concept of VSD transformation for multiphase machines with different phase numbers has been well-addressed in the literature on multiphase machines [26,34,35] and hence not dealt with further in this paper for brevity. To facilitate the subsequent discussion, a symmetrical six-phase induction machine with is used as a case study to represent a multiphase induction machine.…”
Section: Fault-tolerant Control Of Six-phase Induction Machinesmentioning
confidence: 99%
See 1 more Smart Citation
“…For multiphase machines, analysis is usually performed based on the Vector Space Decomposition (VSD) model [33], where the machine variables can be decoupled into fluxand-torque producing α-β components, non-flux-and-torque producing x-y components and zero sequence 0 1 -0 2 components. The concept of VSD transformation for multiphase machines with different phase numbers has been well-addressed in the literature on multiphase machines [26,34,35] and hence not dealt with further in this paper for brevity. To facilitate the subsequent discussion, a symmetrical six-phase induction machine with is used as a case study to represent a multiphase induction machine.…”
Section: Fault-tolerant Control Of Six-phase Induction Machinesmentioning
confidence: 99%
“…The future line of this study includes an investigation of the rapid fault detection schemes [36] incorporating the impact of small transient oscillation and DC offset [34] to be embedded into industrial drives, as well as commercial EVs [35,37].…”
mentioning
confidence: 99%
“…One solution to increase the efficiency and reliability of the generator is to use a multiphase machine with symmetrical [8][9][10][11][12][13] or asymmetrical windings [14][15][16][17][18].…”
Section: Introductionmentioning
confidence: 99%