Post-fault operation of hybrid DC-DC converter for Solid-State Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 14 publications
0
10
0
Order By: Relevance
“…Secondly, with a proper DC-MV to DC-LV converter topology, it can achieve a higher freedom degree of a post fault operation. Especially a three-phase topology of a dual active bridge (DAB) converter with input parallel output parallel (IPOP) connection to the SMs-as shown in Figure 3-is most suitable [22,23]. If a failure in one SM cell occurs, or even if the whole DAB fails, the failed SM can be bypassed.…”
Section: Converter Topologies For the Mv-ac To Mv-dc Stage Of The Sstmentioning
confidence: 99%
“…Secondly, with a proper DC-MV to DC-LV converter topology, it can achieve a higher freedom degree of a post fault operation. Especially a three-phase topology of a dual active bridge (DAB) converter with input parallel output parallel (IPOP) connection to the SMs-as shown in Figure 3-is most suitable [22,23]. If a failure in one SM cell occurs, or even if the whole DAB fails, the failed SM can be bypassed.…”
Section: Converter Topologies For the Mv-ac To Mv-dc Stage Of The Sstmentioning
confidence: 99%
“…e SST circuit is composed of two or more static converters isolated by a transformer that operates at frequency considerably higher than the conventional 50/60Hz. e SST concept is as represented in Figure 5 [8].…”
Section: Concept Of Sst Was Rst Discovered In 1968 Bymentioning
confidence: 99%
“…In addition, the LFT is associated with bulky size and heavy weight. ese disadvantages, coupled with the fact that the emerging grid in electric power system requires new functionalities, controllability and exibility from the distribution make the LFT undesirable [8]. ese and many more constraints of LFT permit researchers to conclude that the conventional transformer cannot effectively meet up with challenges of modern grid [4].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, a crucial part of the ST is a high-frequency (HF) transformer. Depending on the application and power electronics converters included in the ST, the significantly different HF transformers are designed and used [2,6,9]. Such an advanced power electronics device is a challenge in simulation research, caused by many switching elements, making the simulated circuit strongly non-linear.…”
Section: Introductionmentioning
confidence: 99%