2011 IEEE 13th Electronics Packaging Technology Conference 2011
DOI: 10.1109/eptc.2011.6184486
|View full text |Cite
|
Sign up to set email alerts
|

Post cure behaviour of encapsulants for QFN packages processed by an open-ended single mode resonant microwave applicator

Abstract: An open-ended single mode resonant microwave applicator has been developed for the curing of encapsulants materials used for microelectronic packaging. Post cure behaviour of Henkel™ E01080 encapsulant material has been studied by Differential Scanning Calorimetry (DSC), Attenuated Total Reflectance Fourier-Transform Infrared (ATR-FTIR) analysis and Dynamic Mechanical Analysis (DMA). DSC based measurement of the microwave cured samples indicates a ~ 99.2% degree of cure and a glass transition temperature, Tg, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…In the second step, the formed secondary amine reacts with another epoxy group to produce a hydroxyl group and a tertiary amine. Opening of the epoxy ring by an amine to form OH and CN groups [14]. It seems that the chemical mechanism of microwave curing is essentially similar to that of heat curing.…”
Section: Microwave Curingmentioning
confidence: 97%
“…In the second step, the formed secondary amine reacts with another epoxy group to produce a hydroxyl group and a tertiary amine. Opening of the epoxy ring by an amine to form OH and CN groups [14]. It seems that the chemical mechanism of microwave curing is essentially similar to that of heat curing.…”
Section: Microwave Curingmentioning
confidence: 97%
“…The microwave open ended cavity system used for the heat experiments was originally developed to enable rapid bonding of individual microelectronic components on a board assembly [17], [35], [36]. This system has an advantage of volumetric and uniform heating, selective energy deposition with reduced processing times and increased energy efficiency.…”
Section: A Inactivation Of the Virusmentioning
confidence: 99%
“…This system has an advantage of volumetric and uniform heating, selective energy deposition with reduced processing times and increased energy efficiency. Microwave heating was achieved using this open-ended single mode resonant microwave applicator/oven which has been described in [35]. Test specimens consist of 200 µl of Cov-229E-GFP diluted to a multiplicity of infection (MOI) of 0.3 in DMEM, in a cuvette of internal volume 8 mm × 8 mm × 8 mm.…”
Section: A Inactivation Of the Virusmentioning
confidence: 99%