2009
DOI: 10.1016/j.vibspec.2009.04.003
|View full text |Cite
|
Sign up to set email alerts
|

Post-blast detection of traces of explosives by means of Fourier transform infrared spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
19
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 45 publications
(20 citation statements)
references
References 25 publications
1
19
0
Order By: Relevance
“…6. For each sample, the positions of the strongest/unique peaks have been labeled for clarity, and they are in good agreement with FTIR measurements reported in the literature [15][16][17]. The common broad absorption feature around 2720 nm present in all four samples arises due to the O-H stretching vibration of hydroxyl groups from absorbed water in the fused silica host.…”
Section: A Sample Set #1-nestt-tnt Rdx Petn Potassium Nitratesupporting
confidence: 81%
“…6. For each sample, the positions of the strongest/unique peaks have been labeled for clarity, and they are in good agreement with FTIR measurements reported in the literature [15][16][17]. The common broad absorption feature around 2720 nm present in all four samples arises due to the O-H stretching vibration of hydroxyl groups from absorbed water in the fused silica host.…”
Section: A Sample Set #1-nestt-tnt Rdx Petn Potassium Nitratesupporting
confidence: 81%
“…27 However, the high speed of scanning of Raman imaging is usually achieved at the expense of both spatial and spectral resolution, being particularly crucial when extremely large surfaces must be analysed. In fact, these few studies have demonstrated that post-blast residues can be easily detected in small explosions of few grams of explosive performed inside a container, [24][25][26] but extremely complicated when post-blast residues from real open air explosions are spread out over large areas. 23 In this work, confocal Raman microscopy has been studied for the determination of post-blast particles from a large variety of explosives 4 usable in IEDs tackling the analysis of the post-blast residues collected from ten real open-air explosions of ten different explosives.…”
Section: Numerous Dreadful Terrorist Attacks Have Shown the Harm And mentioning
confidence: 99%
“…More than 200 samples containing residue materials collected from various surfaces of objects that were within a close distance from the centre of explosion were prepared. Appropriate data treatment was used before the multivariate analysis (Banas et al 2010).…”
Section: Methodsmentioning
confidence: 99%