2022
DOI: 10.1007/s00202-021-01408-0
|View full text |Cite
|
Sign up to set email alerts
|

Possibilities of the stray current measurement and corrosive risk evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
0
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 25 publications
0
0
0
Order By: Relevance
“…Electrical infrastructure: Electrical infrastructure; like trams, railways, AC power stations, and overhead lines; is one of the major sources of stray currents that cause severe corrosion and failure of the pipelines 65 . In the case of trams and trains, as they act as electrical loads, the electrical circuit is closed, and the current is returned to the traction substation via the running rails.…”
Section: Microbial Activitiesmentioning
confidence: 99%
See 3 more Smart Citations
“…Electrical infrastructure: Electrical infrastructure; like trams, railways, AC power stations, and overhead lines; is one of the major sources of stray currents that cause severe corrosion and failure of the pipelines 65 . In the case of trams and trains, as they act as electrical loads, the electrical circuit is closed, and the current is returned to the traction substation via the running rails.…”
Section: Microbial Activitiesmentioning
confidence: 99%
“…Many factors influencing the stray current intensity were observed on the buried water pipelines, including soil parameters (like resistivity and conductivity that are dependent on soil moisture) and the distance between the pipeline and railways 64 . Stray currents can flow long distances (hundreds of meters to kilometers) from the source types, depending on soil conductivity 65 . For example, the influence of stray currents on the water-pipe network in Kraków, Poland, was obvious despite being around 1 km away from the tramway 16 .…”
Section: Microbial Activitiesmentioning
confidence: 99%
See 2 more Smart Citations
“…In general, the effect of current flow through the interface of a metal with an electrolyte solution (such as the soil itself, or cement for concrete structures) causes corrosion, affecting the solidity and durability of said structures. The first victims are the sleepers and rail fasteners [13][14][15]: in the case of a local insulation loss, they may become a hotspot, with a significant increase in current density, although the overall track leakage may be acceptable over a longer length.…”
Section: Introductionmentioning