1977
DOI: 10.1063/1.323684
|View full text |Cite
|
Sign up to set email alerts
|

Positive column of Na-Ne-Ar ac discharges

Abstract: The positive column of 50-Hz ac discharges in a mixture of sodium vapor and noble gas (99 vol% Ne–1 vol% Ar) has been investigated experimentally. The experimental conditions were as follows: discharge tube radius 10 mm, noble-gas pressure 5.5 Torr at 20°C, and sodium density (2.4–5.7)  × 1019 m−3 which corresponds to a tube wall temperature of 519–538 K. The rms values of the current ranged from 0.25 to 1.5 A. The discharge properties, measured with the aid of electrostatic probes, show hysteresis effects esp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
3
0

Year Published

1977
1977
1986
1986

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…34 Measured V/l curve for sodium/rare-gas discharge showing its multivalued character [50] -t(ms) Fig. 35 Measured electric field E, electron temperature T e and axial electron density N e in sodium-neon discharge [53] 900 mA, 50 Hz, tube diameter 19 mm, neon pressure 730 Pa, tube-wall temperature 530 K and electron density have also been carried out on a discharge operating on a 50Hz supply [52,53]. Fig.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…34 Measured V/l curve for sodium/rare-gas discharge showing its multivalued character [50] -t(ms) Fig. 35 Measured electric field E, electron temperature T e and axial electron density N e in sodium-neon discharge [53] 900 mA, 50 Hz, tube diameter 19 mm, neon pressure 730 Pa, tube-wall temperature 530 K and electron density have also been carried out on a discharge operating on a 50Hz supply [52,53]. Fig.…”
mentioning
confidence: 99%
“…It can be seen that there is a substantial amount of asymmetry in the data. This is due to the fact that the radial ambipolar and neutral atom diffusion time constants, which determine the depletion phenomena, are comparable with the half-cycle time of the mains of 10ms [52,54].…”
mentioning
confidence: 99%
“…The local sodium vapour density can also be determined using other techniques each method having its specific advantages and disadvantages. 3 Lamp voltage control during life With the low pressure sodium discharge lamp one problem which tended to arise was an increase in the lamp voltage during the life of the lamp. If, using the diagnostic techniques in Section 2.…”
mentioning
confidence: 99%