1987
DOI: 10.1007/bf00200380
|View full text |Cite
|
Sign up to set email alerts
|

Positive and negative ion mass spectrometry of benzophenones, the acid-hydrolysis products of benzodiazepines

Abstract: Positive electron impact (EI), positive chemical ionization (CI), and negative CI mass spectra of 14 benzophenones are presented. In the positive EI mode, intense molecular peaks appeared for most compounds; some other peaks due to splitting at both sides of the carbonyl group also appeared. In the positive CI mode, [M + 1]+ quasi-molecular ions together with [M + C2H5]+ peaks were observed for all compounds; some fragment peaks were common to those in the positive EI mode. In the negative CI mode, the spectra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1987
1987
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…In previous reported studies, oxazolobenzodiazepine drugs were determined in the forms of benzophenones after acid hydrolysis [3,[6][7][8], and in their underivatized forms [3,5,9] by GC or GC/MS. Japp et al [3] reported that underivatized oxazolobenzodiazepines easily decomposed during passage through a BP-1 middle-bore capillary column (25 m × 0.22 mm i.d.)…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In previous reported studies, oxazolobenzodiazepine drugs were determined in the forms of benzophenones after acid hydrolysis [3,[6][7][8], and in their underivatized forms [3,5,9] by GC or GC/MS. Japp et al [3] reported that underivatized oxazolobenzodiazepines easily decomposed during passage through a BP-1 middle-bore capillary column (25 m × 0.22 mm i.d.)…”
Section: Resultsmentioning
confidence: 99%
“…Various methods for the determination of benzodiazepines in biological materials have been reported. Analytical methods for underivatized oxazolobenzodiazepines and other benzodiazepines include thin-layer chromatography (TLC) [2,3], high-performance (HP) TLC [4], gas chromatography (GC) [3,[5][6][7], GC-mass spectrometry (MS) [3,5,[7][8][9], high-performance liquid chromatography (HPLC) [3,10,11], and immunoassays [12]. However, simultaneous determination of methylated oxazolobenzodiazepine drugs by GC or GC/MS has not been reported to our knowledge.…”
Section: Introductionmentioning
confidence: 99%
“…The formation of nordiazepam had the potential to lead to a false-positive result that should be interpreted with caution (35). Overall, enzymatic hydrolysis is recommended for benzodiazepine drugs because acid hydrolysis can degrade the drugs to benzophenones and limit accurate drug identification (36). Chemical hydrolysis is a faster procedure in comparison to enzyme hydrolysis; however, acid may cause chromatographic interference by producing high background noise through the generation extra peaks in the chromatogram (37).…”
Section: Hydrolysis Of Benzodiazepine Drugsmentioning
confidence: 99%
“…A forthcoming title [55] presents the spectra (GLC-MS, LC-MS, UV, IR) of the new benzodiazepines described in this article and many metabolites and hydrolysis products. See Suzuki et al [77] for mass spectra of benzophenones and Schtitz et al [70] for infrared spectroscopy.…”
Section: Mass Spectrometrymentioning
confidence: 99%