2023
DOI: 10.3390/s23042072
|View full text |Cite
|
Sign up to set email alerts
|

Portable TDLAS Sensor for Online Monitoring of CO2 and H2O Using a Miniaturized Multi-Pass Cell

Abstract: We designed a tunable diode laser absorption spectroscopy (TDLAS) sensor for the online monitoring of CO2 and H2O concentrations. It comprised a small self-design multi-pass cell, homemade laser drive circuits, and a data acquisition circuit. The optical and electrical parts and the gas circuit were integrated into a portable carrying case (height = 134 mm, length = 388 mm, and width = 290 mm). A TDLAS drive module (size: 90 mm × 45 mm) was designed to realize the function of laser current and temperature cont… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
2

Year Published

2023
2023
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 35 publications
0
4
0
2
Order By: Relevance
“…Allan variance analysis is the most common and widely used tool for estimating the minimum detection limit of TDLAS sensor systems [ 43 ]. The variance supplies detailed information, including the signal stability and noise characteristics of monitoring over different time scales.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Allan variance analysis is the most common and widely used tool for estimating the minimum detection limit of TDLAS sensor systems [ 43 ]. The variance supplies detailed information, including the signal stability and noise characteristics of monitoring over different time scales.…”
Section: Resultsmentioning
confidence: 99%
“…A transparent balloon, filled with methane at a path-integral concentration of 300 ppm•m, is monitored at a detection distance of 10 m for 1200 s. The sampling interval for the TDLAS telemetry sensor is 0.2 s. The 6000 concentration data are successively recorded as shown in Figure 4. Allan variance analysis is the most common and widely used tool for estimating the minimum detection limit of TDLAS sensor systems [43]. The variance supplies detailed information, including the signal stability and noise characteristics of monitoring over different time scales.…”
Section: Precision Estimation Of Tdlas Telemetry Sensorunclassified
“…[97] The CO 2 sensing with detection limit of 0.13 ppm at 18 s response time has been achieved by TDLAS along DFB laser at 2.004 μm and 430 cm multipass cell. [98] 4.1.2. Helicobacter pylori Infection CO 2 and 13 C isotope are the biomarkers of H. pylori infection, bacterial activity in the body and liver malfunction.…”
Section: End-tidal Comentioning
confidence: 99%
“…[ 97 ] The CO 2 sensing with detection limit of 0.13 ppm at 18 s response time has been achieved by TDLAS along DFB laser at 2.004 µm and 430 cm multipass cell. [ 98 ]…”
Section: Applications Of Ir Breath Analysis Over Biomarkersmentioning
confidence: 99%
“…Schroder et al in 2022 proposed a new multispectral NDIR gas sensor capable of achieving a 90% decrease in signal intensity in ten seconds when the concentration was changed and set up for the direct conversion of values to ppm units [ 16 ]. In fact, most of the carbon dioxide detection is focused on air, using optical paths with multiple reflective devices [ 17 , 18 , 19 ]. It is well known that carbon dioxide molecules are polar and interact with other molecules, which affects the sensitivity and accuracy of the sensor.…”
Section: Introductionmentioning
confidence: 99%