2021
DOI: 10.1021/acs.analchem.0c04369
|View full text |Cite
|
Sign up to set email alerts
|

Portable Pen-Probe Analyzer Based on Ion Mobility Spectrometry for in Situ Analysis of Volatile Organic Compounds Emanating from Surfaces and Wireless Transmission of the Acquired Spectra

Abstract: The analysis of volatile organic compounds (VOCs) normally involves sample collection, sample transfer to laboratory, sample preparation, and the chromatographic separation of analytes. However, in some cases, it is impractical or impossible to collect samples prior to the analysis, while the analysis time has to be minimized. Ion mobility spectrometry (IMS) is an ideal technique for a rapid in situ chemical analysis. Here, we present a portable cloud-integrated pen-probe analyzer based on IMS and demonstrate … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 45 publications
0
12
1
Order By: Relevance
“…Here, the robotized PENVOC was coupled with MS; however, suction probes are also readily combined with other spectroscopic tools such as ion-mobility spectrometry ( e.g. , ref ). Thus, it is imaginable that the robotized PENVOC can be coupled with other spectrometers to provide different selectivities, while mapping VOCs.…”
Section: Discussionmentioning
confidence: 99%
“…Here, the robotized PENVOC was coupled with MS; however, suction probes are also readily combined with other spectroscopic tools such as ion-mobility spectrometry ( e.g. , ref ). Thus, it is imaginable that the robotized PENVOC can be coupled with other spectrometers to provide different selectivities, while mapping VOCs.…”
Section: Discussionmentioning
confidence: 99%
“…Drift tube IMS is widely used for rapid profiling of samples containing VOCs ( e.g. , refs ). Similar to the APCI-MS setup, in the case of APCI-IMS setup, the gas flow line downstream from valve 1 was connected to the inlet of the tritium APCI source (Figures E,F).…”
Section: Resultsmentioning
confidence: 99%
“…A prototype of a portable drift tube ion-mobility spectrometer—utilizing multiple low-cost electronic components—was developed previously. 3 The drift tube and the detector (Faraday plate) were fabricated based on the report by Reinecke and Clowers. 40 The system was powered by a lithium battery (24 V, 50 Ah; model no.…”
Section: Methodsmentioning
confidence: 99%
“…In our previous work, the atmospheric pressure chemical ionization (APCI) source was kept in an open-space holder. 3 However, the ionization efficiency was low due to the open-space layout of the ion source. In the present study, we re-designed the ion source holder (Fig.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation