2015
DOI: 10.1038/lsa.2015.119
|View full text |Cite
|
Sign up to set email alerts
|

Portable lensless wide-field microscopy imaging platform based on digital inline holography and multi-frame pixel super-resolution

Abstract: In this paper, an irregular displacement-based lensless wide-field microscopy imaging platform is presented by combining digital in-line holography and computational pixel super-resolution using multi-frame processing. The samples are illuminated by a nearly coherent illumination system, where the hologram shadows are projected into a complementary metal-oxide semiconductor-based imaging sensor. To increase the resolution, a multi-frame pixel resolution approach is employed to produce a single holographic imag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
63
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 108 publications
(63 citation statements)
references
References 60 publications
0
63
0
Order By: Relevance
“…Smartphone and lensless imaging-based disease detection and quantification is another area of immense interest [16,123,124]. The smartphone market is growing at an unprecedented pace.…”
Section: Future Of Paper-based Microfluidic Devicesmentioning
confidence: 99%
“…Smartphone and lensless imaging-based disease detection and quantification is another area of immense interest [16,123,124]. The smartphone market is growing at an unprecedented pace.…”
Section: Future Of Paper-based Microfluidic Devicesmentioning
confidence: 99%
“…Existing SR processing techniques applied in lensless imaging systems are mainly based on multi-frame reconstruction, in which multiple LR cell images with sub-pixel motions of the same object are synthesized into one single HR cell image. The sub-pixel motions can be generated by either flowing the cell samples through the microfluidic channel, shifting the light source, or sequentially activating multiple light sources at different locations [7,13,14]. However, the main problem for multi-frame SR is that the system needs to continuously capture, store, and process multiple LR images in order to recover one HR image, which not only limits the practical detection throughput but also requires large storage.…”
Section: Introductionmentioning
confidence: 99%
“…Fourth, in this study, sexual assault kit samples were visualized using a standard laboratory microscope. The next generation of this platform can potentially be integrated with a portable imaging system,40 enabling easy access to the technology in remote locations for sexual assault evidence screening. Fifth, we decorated channels with SLeX monomer units in the current study.…”
Section: Resultsmentioning
confidence: 99%