2016
DOI: 10.5603/fm.a2015.0094
|View full text |Cite
|
Sign up to set email alerts
|

Porcine liver vascular bed in Biodur E20 corrosion casts

Abstract: Background: Pigs are frequently used as animal models in experimental medicine. To identify processes of vascular development or regression, vascular elements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(24 citation statements)
references
References 16 publications
(21 reference statements)
0
24
0
Order By: Relevance
“…Resins that cure to more resilient, flexible types of casts are for instance Biodur E20 Plus (Biodur Products GmbH) or PU4ii (VasQtec). Biodur E20 Plus is an epoxy‐based resin with a viscosity of about 170–190 mPas (Eberlova et al, ) that can be used to cast similar types of specimens as for the Batson's #17 kit, and to which a specific plasticizer (Biodur AE 20) can be added to even increase the flexibility of the resulting cast. PU4ii, a polyurethane resin, is mainly used in microvascular corrosion cast studies.…”
Section: Choice Of Casting Mediummentioning
confidence: 99%
See 3 more Smart Citations
“…Resins that cure to more resilient, flexible types of casts are for instance Biodur E20 Plus (Biodur Products GmbH) or PU4ii (VasQtec). Biodur E20 Plus is an epoxy‐based resin with a viscosity of about 170–190 mPas (Eberlova et al, ) that can be used to cast similar types of specimens as for the Batson's #17 kit, and to which a specific plasticizer (Biodur AE 20) can be added to even increase the flexibility of the resulting cast. PU4ii, a polyurethane resin, is mainly used in microvascular corrosion cast studies.…”
Section: Choice Of Casting Mediummentioning
confidence: 99%
“…Most often, it is referred to as essential to rinse the system to prevent residual blood to form clots that may obstruct the downstream channels. Often, it is also recommended to add heparin to the rinsing solution for the same reason (Eberlova et al, ). However, in a study performed by Martin‐Orti et al (), no beneficial effects of the anticoagulant or rinsing step on the complete filling of the vascular system could be observed.…”
Section: Principles and Technique Of Corrosion Castingmentioning
confidence: 99%
See 2 more Smart Citations
“…Mapping of the volume fractions of the main porcine liver components remains to be performed. As shown in recent studies (Debbaut et al 2012(Debbaut et al , 2014b, this may be done economically by combining the histological approach with a three-dimensional analysis and stereological quantification of hepatic microvessels using high-resolution X-ray microtomography of vascular corrosion casts (Eberlova et al 2016;Ji r ık et al 2016). Moreover, quantitative data regarding the size and density of hepatocytes may also be combined with multilevel modeling of hepatic perfusion (Debbaut et al 2014a;Peeters et al 2015).…”
Section: Distribution Of Larger Mnhep Correlates With a Larger Volumementioning
confidence: 99%