2010
DOI: 10.1021/ie101265e
|View full text |Cite
|
Sign up to set email alerts
|

Polyvinyl Chloride and Halogen-free Electric Wires Thermal Decomposition

Abstract: A kinetic model for the pyrolysis and combustion of PVC and halogen-free electric wires has been obtained. One set of parameters can explain all the experiments at the different atmospheres and at the three different heating rates used. Thermal analysis of different parts of the cable, cover, insulation and conductive metal, both separately and combined, has allowed for understanding of the interaction between the different materials.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
13
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 18 publications
2
13
0
Order By: Relevance
“…For all the fractions (1 to 3), the same values of apparent activation energy and reaction order obtained under a nitrogen atmosphere have been considered, but the preexponential factor could change due the presence of the oxygen. This type of model satisfactorily fitted the decomposition of other materials [16,17]. With all these considerations, acceptable correlations of the data are obtained.…”
Section: Kinetic Modelsupporting
confidence: 54%
“…For all the fractions (1 to 3), the same values of apparent activation energy and reaction order obtained under a nitrogen atmosphere have been considered, but the preexponential factor could change due the presence of the oxygen. This type of model satisfactorily fitted the decomposition of other materials [16,17]. With all these considerations, acceptable correlations of the data are obtained.…”
Section: Kinetic Modelsupporting
confidence: 54%
“…For all the fractions (1 to 3), the same values of apparent activation energy and reaction order obtained under a helium atmosphere have been considered, but the pre-exponential factor is assumed to be different due to the presence of the oxygen. This type of model satisfactorily fitted the decomposition of other materials [13,14]. With all these considerations, acceptable correlations of the data are obtained.…”
Section: Kinetic Model For Pyrolysis and Combustion Processessupporting
confidence: 54%
“…In a previous work [ 5], emission tests were performed on the thermal decomposition of PVC and halogen-free electrical wires, pointing out the important quantities of poly-chlorinated dioxins and furans emitted in uncontrolled processes. On the contrary, a reduced amount of pollutants was measured in the halogen-free electrical wires thermal decomposition.…”
Section: Introductionmentioning
confidence: 99%
“…This technique has been widely used to study the thermal decomposition of different waste electrical and electronic equipment, given that the TG curves provide information on the mechanisms of decomposition of the sample and allow for calculate the kinetic parameters of the reaction that has taken place [5].…”
Section: Introductionmentioning
confidence: 99%