1994
DOI: 10.1007/bf00708991
|View full text |Cite
|
Sign up to set email alerts
|

Polymeric membrane sodium-selective electrodes based on calix[4]arene ionophores

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1998
1998
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Subsequently, the use of a large number of calix[4]arene derivatives for potentiometric measurements has been reported. Only minor changes in selectivities were found for other p - tert -butylcalix[4]aryl tetraesters, but some improvements were obtained with short-chain esters and a mixed-ester compound (two decyl and two ethyl groups each ( Na + -21 ): log (SSM): K + , −2.6; Li + , −3.5; H + , −4.0; DOP, NaTFPB). , However, better selectivities resulted from the use of a calix[4]aryl tetraester with tert -octyl instead of tert -butyl groups ( Na + -22 , log (SSM): K + , −3.1; Li + , −4.6; Rb + , −5.1; Cs + , −5.8; FNDPE, KTpClPB) . Tetraesters have been tested for blood serum assays. ,,,
…”
Section: Na+ Sensorsmentioning
confidence: 99%
“…Subsequently, the use of a large number of calix[4]arene derivatives for potentiometric measurements has been reported. Only minor changes in selectivities were found for other p - tert -butylcalix[4]aryl tetraesters, but some improvements were obtained with short-chain esters and a mixed-ester compound (two decyl and two ethyl groups each ( Na + -21 ): log (SSM): K + , −2.6; Li + , −3.5; H + , −4.0; DOP, NaTFPB). , However, better selectivities resulted from the use of a calix[4]aryl tetraester with tert -octyl instead of tert -butyl groups ( Na + -22 , log (SSM): K + , −3.1; Li + , −4.6; Rb + , −5.1; Cs + , −5.8; FNDPE, KTpClPB) . Tetraesters have been tested for blood serum assays. ,,,
…”
Section: Na+ Sensorsmentioning
confidence: 99%
“…Absorbent patches, microfluidic channels, and per-use washing may be considered as possible solutions. Second, selectivity of the ISEs against simple nontarget ions like K + , H + , and NH 4 + is likely to be high, as has been reported earlier. However, selectivity against other constituents of sweat, especially lipophilic substances that can diffuse into the ISM, needs to be studied. Artificial sweat with controlled compositions can be used in such studies.…”
Section: Resultsmentioning
confidence: 84%
“…To make this material sensitive toward Na + ions, it was doped with 4- tert -butylcalix­[4] arene-tetraacetic acid tetraethyl ester (sodium ionophore X) and ion exchanger potassium tetrakis­((4-chlorophenyl)­borate , (Figure S1). Sodium ionophore X was chosen owing to its high sensitivity to Na + ion and high selectivity against similar ions, such as K + and H + . CNT-based flexible electrode arrays were prepared following a scheme shown in Figure a. The process utilizes standard photolithography and laser-cutting techniques.…”
Section: Resultsmentioning
confidence: 99%