2014
DOI: 10.1016/j.bios.2014.05.014
|View full text |Cite
|
Sign up to set email alerts
|

Polymer-based, flexible glutamate and lactate microsensors for in vivo applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
96
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 96 publications
(105 citation statements)
references
References 34 publications
2
96
0
2
Order By: Relevance
“…We also adopted a design of micro-wells around electrodes creating a steric barrier for H 2 O 2 diffusion out of the well. Although the micro well design had been already proposed in previous works (Frey et al, 2010;Weltin et al, 2014), this is, to our knowledge the first study using only SU8 to create the boundaries between wells. The SU8 resist allowed a large range of possible thicknesses easily achievable by modifying photolithography conditions practical for optimizing the microwells design.…”
Section: Multi-electrode Integration On the Silicon Micro-needlementioning
confidence: 95%
See 2 more Smart Citations
“…We also adopted a design of micro-wells around electrodes creating a steric barrier for H 2 O 2 diffusion out of the well. Although the micro well design had been already proposed in previous works (Frey et al, 2010;Weltin et al, 2014), this is, to our knowledge the first study using only SU8 to create the boundaries between wells. The SU8 resist allowed a large range of possible thicknesses easily achievable by modifying photolithography conditions practical for optimizing the microwells design.…”
Section: Multi-electrode Integration On the Silicon Micro-needlementioning
confidence: 95%
“…Most of the reported planar devices allowed monitoring of only one analyte with half of the microelectrodes devoted to enzymatic sensing and the other half devoted to the control of non-specific currents (Rutherford et al, 2007;Wassum et al, 2008;Weltin et al, 2014). A few reports demonstrated successful parallel recordings of choline and acetylcholine (Burmeister et al, 2008) or glutamate and non-specific (control) current (Frey et al, 2010) using multi-sensing micro-arrays without significant cross-talk between recording sites.…”
Section: Introductionmentioning
confidence: 96%
See 1 more Smart Citation
“…A recent report of an in vivo flexible strip microelectrode sensor array for glutamate and lactate monitoring in tissue represents an advance [44]. The polyimide substrate was patterned with platinum microelectrodes in addition to epoxy and dry film insulations to produce amperometric, enzyme-based sensors.…”
Section: Electrode Arrays Modified With Enzymesmentioning
confidence: 99%
“…We fabricated a disposable multi-sensor platform in a cost-effective hybrid of thin-film and laminate technology ( Figure 1). Chip fabrication, including electrode modification and deposition of a Ag/AgCl on-chip reference electrode, was done on a wafer-level as described previously [4,5]. For sensor integration, glutamate oxidase was stably immobilized on platinum thin-film electrodes by chemical crosslinking into a protein matrix (Figure 1).…”
Section: Chip and Sensor Fabricationmentioning
confidence: 99%