2013
DOI: 10.1016/j.jhazmat.2013.07.018
|View full text |Cite
|
Sign up to set email alerts
|

Polyelectrolyte complex/PVA membranes for diffusion dialysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
45
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 74 publications
(48 citation statements)
references
References 34 publications
1
45
2
Order By: Relevance
“…The S value for membrane TPA-0 is found to be 6.34. Similarly the obtained S values for membrane TPA-35 to TPA-47 are in the range of 21.9-38.8 which suggested that the S value for membrane TPA-47 is almost similar to that of PVA-based hybrid membranes (22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39) at 25°C [22], (12.1-35.7) at 25°C [16] and (18.5-21) at 25°C [21]. Even obtained S values for membranes TPA-43 and TPA-47 are much higher than that of [14].…”
Section: Dd For Hcl/fecl 2 Solutionsupporting
confidence: 54%
See 1 more Smart Citation
“…The S value for membrane TPA-0 is found to be 6.34. Similarly the obtained S values for membrane TPA-35 to TPA-47 are in the range of 21.9-38.8 which suggested that the S value for membrane TPA-47 is almost similar to that of PVA-based hybrid membranes (22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39) at 25°C [22], (12.1-35.7) at 25°C [16] and (18.5-21) at 25°C [21]. Even obtained S values for membranes TPA-43 and TPA-47 are much higher than that of [14].…”
Section: Dd For Hcl/fecl 2 Solutionsupporting
confidence: 54%
“…Water uptake of a membrane has an important impact related to its separation phenomena, mechanical and dimensional properties [29,30]. As shown in Fig.…”
Section: Water Uptake (Wu Linear Expansion Ration (Ler) and Ion Exchmentioning
confidence: 99%
“…In our research group, numerous efforts have been rendered towards the improvement of high performance anion exchange membranes with different polymer matrix and accordingly DD performance of synthesized membranes were investigated by evaluating the dialysis coefficient of HCl (U H ) and separation factor (S). U H and S values of different membranes for acid recovery (HCl/FeCl 2 ) via DD process of previously published works [6][7][8][9][10][11][12][13][14] were summarized in Table 1. In our research group, semi-homogeneous membranes were developed to overcome the restrictions facing by the heterogeneous membrane such as high cost and limited applications [15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…However, the preparation of the multisilicon copolymers is through conventional radical polymerization technique, which lacks effective control over the polymer architectures, compositions, and functionalities [21]. Another problem with multisilicon copolymer is that they tend to become gel during preparation and preservation [12,22] due to the pre-hydrolysis and condensation of the -Si(OR) 3 groups, which is disadvantageous to practical applications.…”
Section: Introductionmentioning
confidence: 99%