2008
DOI: 10.1088/0022-3727/41/20/205203
|View full text |Cite
|
Sign up to set email alerts
|

Polydiagnostic calibration performed on a low pressure surface wave sustained argon plasma

Abstract: The electron density and electron temperature of a low pressure surface wave sustained argon plasma have been determined using passive and active (laser) spectroscopic methods simultaneously. In this way the validity of the various techniques is established while the plasma properties are determined more precisely. The electron density, ne, is determined with Thomson scattering (TS), absolute continuum measurements, Stark broadening and an extrapolation of the atomic state distribution function (ASDF). The ele… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
9
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 35 publications
4
9
0
Order By: Relevance
“…[5]. The agreement with ACI measurements proves that this method is also reliable for the n e -determination.…”
Section: Electron Density Resultssupporting
confidence: 69%
See 1 more Smart Citation
“…[5]. The agreement with ACI measurements proves that this method is also reliable for the n e -determination.…”
Section: Electron Density Resultssupporting
confidence: 69%
“…The detection branch used for the OES is described in detail in [5]. The emitted plasma light is focused into an optical fiber, by which the light is guided to the entrance slit of a spectrometer.…”
Section: Passive Spectroscopy Detection Branchmentioning
confidence: 99%
“…To this end, vertical diodes are routinely fabricated with relatively large active area in the range of 0.001-1 cm 2 , which leads to large C j values. In contrast, in the coplanar diodes shown in Figure 1 b, the active area is defi ned by the thickness of the asymmetric electrodes employed times the nanogap length ( W ), although the extrinsic capacitance due to the 3D coupling of the electrodes through the substrate/air, must also be considered [ 15 ] (see Figure S1, Supporting Information). However, even when taking this parasitic contribution into account, and even for devices with extremely large W / d ratio (>10 000), this geometrical alteration translates to a dramatic drop in C j , potentially enabling sub-pF device capacitances and a corresponding increase in f CO .…”
mentioning
confidence: 99%
“…The reported value of T g = 520 K leads to a gas density n a = 1.4 × 10 25 m −3 . For the determination of truetrueTˆe, we use the method described in . In short, trueTˆe is determined by combining the density n(1) of the argon ground state with that of the densities n(4p) of the argon 4p levels.…”
Section: Methods and Theoretical Backgroundmentioning
confidence: 99%