2020
DOI: 10.1002/bkcs.12163
|View full text |Cite
|
Sign up to set email alerts
|

Polydiacetylenes Containing 2‐Picolylamide Chemosensor for Colorimetric Detection of Cadmium Ions

Abstract: This article describes the preparation and analysis of Cd 2+-sensing polydiacetylene-based chemosensors (PDA-MP). Polydiacetylenes (PDAs), a family of conjugated polymers, exhibit a strong response to external stimuli. Accordingly, we have designed a novel PDA sensor, which is linked to mono 2-picolylamine, to increase the PCDA-MP monomer content in polymer system. As a result, it enhanced sensitivity toward Cd 2+ with the low detection limit (2.10 μM) in aqueous solution. Our sequential modification of chelat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…Conjugated polymers (CPs) are π-conjugated macromolecules with delocalized-π-electronic systems along the polymer chain. Because of extended conjugation, CPs showed high absorption coefficient, bright fluorescence, photostability, but are hydrophobic. Therefore, they have been intensively applied in biosensor, bioimaging, and drug delivery after appropriate modifications by incorporating with cationic, anionic, or polar units on the side chains .…”
Section: Representative Strategies For Conventional Photosensitizersmentioning
confidence: 99%
“…Conjugated polymers (CPs) are π-conjugated macromolecules with delocalized-π-electronic systems along the polymer chain. Because of extended conjugation, CPs showed high absorption coefficient, bright fluorescence, photostability, but are hydrophobic. Therefore, they have been intensively applied in biosensor, bioimaging, and drug delivery after appropriate modifications by incorporating with cationic, anionic, or polar units on the side chains .…”
Section: Representative Strategies For Conventional Photosensitizersmentioning
confidence: 99%
“…To further increase the sensitivity, the authors designed the PDA-based sensor with different DA monomer compositions by using mono 2-picolylamine (MP) as a head group modification on PCDA (PCDA-MP). 60 This led to an increase in Cd 2+ sensitivity with a LOD of 2.1 μM while retaining the high selectivity of the PDA sensors to other metal ions. For the detection of Pb 2+ , recognition moieties such as dopamine, 61 galloyl, 62 1-aza-18-crown-6-ether, 63 and glycine 64 have been incorporated into PDA-based sensors for selective and sensitive detection of Pb 2+ at as low as 0.24 μM.…”
Section: Polydiacetylene-based Sensors For Food Applicationsmentioning
confidence: 98%