1996
DOI: 10.1016/0924-0136(95)01891-3
|View full text |Cite
|
Sign up to set email alerts
|

Polycrystalline diamond edge quality and and surface integrity following electrical discharge grinding

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
21
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 2 publications
0
21
0
Order By: Relevance
“…Published papers detailing the EDM of PCD are reasonably extensive [10][11][12], however as far as the authors are aware, there is very little information available dealing specifically with the sparking of CVD diamond, although work on single crystal natural diamond is relevant [13,14]. The electrical resistivity values for conductive CVD diamond (CVDITE CDE) and PCD are up to 1000 [15] and 14,700 cm [16], respectively.…”
Section: Electrical Discharge Machiningmentioning
confidence: 99%
“…Published papers detailing the EDM of PCD are reasonably extensive [10][11][12], however as far as the authors are aware, there is very little information available dealing specifically with the sparking of CVD diamond, although work on single crystal natural diamond is relevant [13,14]. The electrical resistivity values for conductive CVD diamond (CVDITE CDE) and PCD are up to 1000 [15] and 14,700 cm [16], respectively.…”
Section: Electrical Discharge Machiningmentioning
confidence: 99%
“…Published papers detailing the EDM of PCD are reasonably extensive [12][13][14], however as far as the authors are aware, there is very little information available dealing specifically with the EDM of CVD diamond [11], although work on single crystal natural diamond is available [15]. Previous research by the authors has shown that doped CVD diamond is machinable using EDM, however at relatively low cutting speeds (∼50% of PCD) [16].…”
Section: Introductionmentioning
confidence: 98%
“…The problem in using a form and roughness tester is positioning, orienting and fixturing the diamond grain as well as the morphological errors coming from the stylus and fixture. A tactile profilometer is used in [9] for measurement of the edge quality of the polycrystalline diamonds. For SEM, the problem is the non-conductivity of the diamond; therefore always sample preparation have to be done and special consideration must be given to have a homogenous and thin layer of metallic coating on very clean diamond samples.…”
Section: Introductionmentioning
confidence: 99%