2004
DOI: 10.1016/j.aca.2004.07.052
|View full text |Cite
|
Sign up to set email alerts
|

Poly (methacrylic acid–ethylene glycol dimethacrylate) monolithic capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography and its application to determination of basic drugs in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
111
0
1

Year Published

2006
2006
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 162 publications
(116 citation statements)
references
References 24 publications
4
111
0
1
Order By: Relevance
“…was a little more complex. Before filling the pre-polymerization mixture into it, the capillary was required to first derivatize with 3-(triethoxysilyl)propyl methacrylate [44] and then dried with N 2 . The following procedure was the same as the above description.…”
Section: Preparation Of Poly(aa-vp-bis) Monolithic Extraction Columnmentioning
confidence: 99%
See 1 more Smart Citation
“…was a little more complex. Before filling the pre-polymerization mixture into it, the capillary was required to first derivatize with 3-(triethoxysilyl)propyl methacrylate [44] and then dried with N 2 . The following procedure was the same as the above description.…”
Section: Preparation Of Poly(aa-vp-bis) Monolithic Extraction Columnmentioning
confidence: 99%
“…Because the in-tube SPME-HPLC system used in this study and its operation procedures have been described in detail in the previous papers [44][45][46], they will not be discussed here. The whole system consists of a pre-extraction segment and an analytical segment.…”
Section: Instrumentation and Analytical Conditionsmentioning
confidence: 99%
“…Thus, the SPME fiber coatings with such properties are definitely in demand; the efforts in this field should be further strengthened. The research on monolith materials is a hot topic in analytical chemistry in recent years, but their application in the SPME field is very limited (101,102). However, we believe that the SPME fiber coatings based on monolith materials should have a bright future because of their unique properties, such as very rapid extraction kinetics, high extraction effect, and good compatibility with biological samples.…”
Section: Resultsmentioning
confidence: 99%
“…The poly(MAA-co-EDMA) column was prepared as reported by Fan et al 24 The blank urine sample was collected and preprocessed as reported by Zheng et al 25 The preprocessed blank urine sample was directly spiked with CLB and diluted two times with 20 mM phosphate buffer (pH = 7.0) to get the final CLB concentrations of 50, 150 and 250 μg/L.…”
Section: Preparations Of Spe Column and Urine Samplesmentioning
confidence: 99%
“…As a result, we deemed the acceptable sample flow rate should be lower than 45 μL/min. As the effluent flow rates are typically in the range of 3.3 -40 μL/min in the SPE using the capillary columns, 15,24,26,27 the acceptable flow rate of 45 μL/min is sufficient for the coupling between the microcolumn SPE and CE in practice.…”
Section: Operation Parameters Of the μ-Tfgimentioning
confidence: 99%