2018
DOI: 10.1016/j.talanta.2017.08.030
|View full text |Cite
|
Sign up to set email alerts
|

Poly (methacrylic acid-co-diethenyl-benzene) monolithic microextraction column and its application to simultaneous enrichment and analysis of mycotoxins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(14 citation statements)
references
References 40 publications
0
13
0
1
Order By: Relevance
“…However, LODs were higher (0.69-2.03 µ g/L) than the ones obtained by MS or in the work previously described for the analysis of aflatoxins by HPLC-PDA [80]. Nonetheless, the separation of the three mycotoxins was achieved in less than 6 min and recovery values were successful for all the analytes assayed [79].…”
Section: Solid-phase Microextraction (Spme)mentioning
confidence: 54%
See 2 more Smart Citations
“…However, LODs were higher (0.69-2.03 µ g/L) than the ones obtained by MS or in the work previously described for the analysis of aflatoxins by HPLC-PDA [80]. Nonetheless, the separation of the three mycotoxins was achieved in less than 6 min and recovery values were successful for all the analytes assayed [79].…”
Section: Solid-phase Microextraction (Spme)mentioning
confidence: 54%
“…Aflatoxins were separated in 10 min and the method exhibited good sensitivity with LODs values in the range 0.061-0.074 µ g/L. In addition, more recently, an in-tube SPME strategy has been proposed for the simultaneous multicomponent extraction of three different mycotoxins (aflatoxin B1, zearalenone and sterigmatocystin) from rice samples [79]. For this purpose, a poly(methacrylic acid-co-divinylbenzene) monolithic column was prepared and applied as SPME fiber for the extraction of the target analytes, which were subsequently analyzed by HPLC-PDA.…”
Section: Solid-phase Microextraction (Spme)mentioning
confidence: 99%
See 1 more Smart Citation
“…Because of that, the use of monolithic columns has been growing when compared with packed cartridges. Wu et al [28] synthesized a monolithic column based on poly(metacrylic acid-co-divinyl-benzene) for IT SPME. The monolithic extraction column was synthesized inside a fused silica capillary with 250 μm of id and 20 cm of length.…”
Section: Fused Silicamentioning
confidence: 99%
“…Wu et al. synthesized a monolithic column based on poly(metacrylic acid‐ co ‐divinyl‐benzene) for IT SPME. The monolithic extraction column was synthesized inside a fused silica capillary with 250 μm of id and 20 cm of length.…”
Section: Extraction Columnsmentioning
confidence: 99%