Pole‐to‐ground fault current estimation in symmetrical monopole high‐voltage direct current grid considering modular multilevel converter control

Abstract: This Letter proposed a novel method to accurately estimate the pole-toground fault current in symmetrical monopole high-voltage direct current grids. To avoid simulation's time consuming and difficult modelling, the converter is equivalent to the simple resistor LC circuit, and the state space including negative pole and positive pole is established for pole-to-ground current estimation. To enhance the accuracy of the estimation, the influence of converter control is considered in the estimation. It is found t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…As indicated in [27], the DC grid topology impacts the fault current mainly through the equivalent impedance. Thus, the impact of the grid topology on the fault current can be investigated by analyzing the grid equivalent impedance.…”
Section: B Impact Analysis Of Grid Topology On Fault Current Based On...mentioning
confidence: 99%
“…As indicated in [27], the DC grid topology impacts the fault current mainly through the equivalent impedance. Thus, the impact of the grid topology on the fault current can be investigated by analyzing the grid equivalent impedance.…”
Section: B Impact Analysis Of Grid Topology On Fault Current Based On...mentioning
confidence: 99%
“…Write the above equation in matrix form as shown in (8), where the Jacobian matrix and determinant J dc is shown in the following equation…”
Section: Bnode Admittance Matrix and Power Flow Equationmentioning
confidence: 99%
“…Building a future DC power grid faces some key technical challenges [7]. On the one hand, the development of key equipment, including high-voltage DC circuit breakers and DC/DC converters, is a key core issue that must be addressed in the DC power grid [8]. On the other hand, due to the small response time constant of the DC power grid, new and higher requirements have been put forward for the simulation of the DC power grid system [9], the operation control and protection technology of the DC power grid, and the rapid fault detection technology of the DC power grid.…”
Section: Introductionmentioning
confidence: 99%
“…The power transmission between the AC system and the MMC remains controllable in a short period after the fault due to the PI controller [23]. Therefore, when the MMC operates in the power control mode, Pdc is thought to be equal to Pref in the early fault time [17,24]. As a result, is is almost unchanged and can be solved as…”
Section: Equivalent Model Of MMC Under Dc Faultsmentioning
confidence: 99%