2011
DOI: 10.1016/j.ijepes.2010.12.019
|View full text |Cite
|
Sign up to set email alerts
|

Pole placement by coordinated tuning of Power System Stabilizers and FACTS-POD stabilizers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
27
0
4

Year Published

2012
2012
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(31 citation statements)
references
References 24 publications
0
27
0
4
Order By: Relevance
“…Reddy et al [27] proposed a state feedback controller utilizing the secondary bus voltage of the step-up transformer as reference instead of the infinite bus. Furini et al [28] used pole placement for the design of PSS for multi-machine power systems in coordination with FACTS devices. Mostafa et al [29] proposed PSS for interconnected power systems tuned by particle swarm optimization.…”
Section: Introductionmentioning
confidence: 99%
“…Reddy et al [27] proposed a state feedback controller utilizing the secondary bus voltage of the step-up transformer as reference instead of the infinite bus. Furini et al [28] used pole placement for the design of PSS for multi-machine power systems in coordination with FACTS devices. Mostafa et al [29] proposed PSS for interconnected power systems tuned by particle swarm optimization.…”
Section: Introductionmentioning
confidence: 99%
“…Genetic algorithms (GA) [3], Tabu search (TS) [4], simulated annealing [5] evolutionary programming [6] have been proposed to design PSS parameters. In [7], an adaptive network based fuzzy inference system (ANFIS) is used to improve the power system damping via SVC. In [8], a new scheme is proposed to find optimal location of SVCs to increase power system stability.…”
Section: Introductionmentioning
confidence: 99%
“…The adjusted design of PSSs and SVC based on probabilistic theory is described in [14]. In [15], the decentralized modal control technique is applied to pole placement in multimachine power system using FACTS devices. In [16], an extensive evaluation is performed on PSS and FACT device independently as well as in a coordinated mode.…”
Section: Introductionmentioning
confidence: 99%
“…Several researches have been carried out for the coordination between PSSs and FACTS damping controllers. Some of these researches were depending on the complex nonlinear simulation while the others based on the linearized model for power system [11][12][13][14][15][16][17]. One approach for achieving the required performance is to make the coordinated design of the controller as a constrained optimization problem.…”
Section: Introductionmentioning
confidence: 99%