2005
DOI: 10.1016/j.ab.2005.03.024
|View full text |Cite
|
Sign up to set email alerts
|

Polarographic measurement of hydrogen sulfide production and consumption by mammalian tissues

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
229
0
5

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 334 publications
(241 citation statements)
references
References 45 publications
7
229
0
5
Order By: Relevance
“…H 2 S is rapidly consumed in gills and gill mitochondria from sulfide-adapted mussel, Geukensia demissa, in normoxic conditions but reduced 50-fold by anoxia (79). In rat tissues, O 2 either inhibits H 2 S production or it may be associated with H 2 S consumption and both are reversed by hypoxia (30,44). Similar observations have been made in a variety of tissues from numerous vertebrates (32,89,94,126,128,186).…”
Section: Inverse Relationship Between O 2 and H 2 Ssupporting
confidence: 64%
“…H 2 S is rapidly consumed in gills and gill mitochondria from sulfide-adapted mussel, Geukensia demissa, in normoxic conditions but reduced 50-fold by anoxia (79). In rat tissues, O 2 either inhibits H 2 S production or it may be associated with H 2 S consumption and both are reversed by hypoxia (30,44). Similar observations have been made in a variety of tissues from numerous vertebrates (32,89,94,126,128,186).…”
Section: Inverse Relationship Between O 2 and H 2 Ssupporting
confidence: 64%
“…NaHS was used in initial experiments whereas Na 2 S was used in later studies as it was more readily available and has fewer sulfur impurities (Doeller et al, 2005). Both salts form HS -and H 2 S when dissolved and we have not noticed any obvious differences in the effects produced by these salts .…”
Section: H 2 S Responsesmentioning
confidence: 99%
“…[77][78][79] Given the high reactivity of H 2 S in biological environments, traditional detection methods, e.g., colorimetric/electrochemical assays, gas chromatography, and sulfide precipitation, could yield inconsistent results due to lengthy and/or destructive procedures. [80][81][82][83] Consequently, the reported biologically relevant concentrations of H 2 S vary over a 10 5 -fold range, from 100 pM to 300 mM. 81,[84][85][86][87][88] Recent reports described several small-molecule fluorescent probes for H 2 S detection in living systems.…”
Section: Hydrogen Sulfide (H 2 S) Sensorsmentioning
confidence: 99%