2018 International Conference on Applied Smart Systems (ICASS) 2018
DOI: 10.1109/icass.2018.8651972
|View full text |Cite
|
Sign up to set email alerts
|

Point on Voltage Wave Switching for Sympathetic Inrush Current Reduction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…The laboratory tests conducted in order to quantify the peak value of the inrush current, to prevent some situations of failure require great expense and are not being performed. For this reason, analytical methods and the simulation of the phenomenon were used to determine the magnitude of the transient current generated when wiring the transformer, to avoid possible damage and to choose the adequate protections [18][19][20][21][22][23][24][25].…”
Section: The Inrush Current Generated On High-power Transformer Wiringmentioning
confidence: 99%
See 1 more Smart Citation
“…The laboratory tests conducted in order to quantify the peak value of the inrush current, to prevent some situations of failure require great expense and are not being performed. For this reason, analytical methods and the simulation of the phenomenon were used to determine the magnitude of the transient current generated when wiring the transformer, to avoid possible damage and to choose the adequate protections [18][19][20][21][22][23][24][25].…”
Section: The Inrush Current Generated On High-power Transformer Wiringmentioning
confidence: 99%
“…the thermal assessment is aimed at the faster-than-anticipated aging due to the excess temperatures caused by the hot spot of the winding, the hot spot in the core and the defects of paper-insulated hot metals; 2. dielectric evaluation follows the process of degradation of solid / liquid insulation due to high thermal or electrical voltage, moisture in the paper / dielectric liquid, manufacturing defects and contamination with conductive particles; 3. the mechanical assessment is aimed at the disintegration of the structure in the core, the windings and the solid insulation, due to one of the many reasons, such as the strong electromagnetic forces resulting from the flow of short-circuit current through the windings; the mechanical deformation of the windings due to the shocks during transportation, installation or during system failures, etc. ; and the degradation of solid insulating materials [16][17][18][19][20][21][22][23][24][25]. Some of the operations concerning the maintenance of power transformers can be established following the modeling of the transient phenomena, starting with the design stage.…”
Section: Introductionmentioning
confidence: 99%
“…To measure the inrush current in a three-phase transformer, a laboratory experimental setup with an acquisition system (dSPACE card) is detailed and presented in this article. The technique presented and proposed by Yahiou et al [20,21] has exploited to reduce the three-phase transformer transient current. This technique is based on Faraday's law to estimate the magnetic flux waveform via the voltage waveform, then the value of residual flux at the de-energizing moment (the circuit breaker is open) is estimated.…”
Section: Introductionmentioning
confidence: 99%