Point-of-Need Disposable ELISA System for COVID-19 Serology Testing

Abstract: A disposable enzyme-linked immunosorbent assay (dELISA) device for ate-home or doctor’s office use was developed to detect SARS-CoV-2 antibodies. Serology testing for SARS-CoV-2 antibodies is currently run using well-plate ELISAs in centralized laboratories. However, the scale of serology testing needed for epidemiological and clinical screening studies will overwhelm existing clinical laboratory resources. Instead, a point-of-need device that can be used at home or in doctor’s offices for COVID-19 serology te… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 1 publication
0
9
0
Order By: Relevance
“…This observation is consistent with results published by our group and others. 37 , 42 , 43 Following plasma delivery to the NCM and a subsequent buffer wash ( Figure 2 B), the yellow dye that had dried on the reagent pad to mimic the HRP-antibody was released through the HRP-antibody delivery channel and flowed to the detection zone ( Figure 2 C, 12 min). Simultaneously, buffer flowed through the hydration channel to keep the blood-filtration membrane hydrated, driving the flow to the NCM.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…This observation is consistent with results published by our group and others. 37 , 42 , 43 Following plasma delivery to the NCM and a subsequent buffer wash ( Figure 2 B), the yellow dye that had dried on the reagent pad to mimic the HRP-antibody was released through the HRP-antibody delivery channel and flowed to the detection zone ( Figure 2 C, 12 min). Simultaneously, buffer flowed through the hydration channel to keep the blood-filtration membrane hydrated, driving the flow to the NCM.…”
Section: Resultsmentioning
confidence: 99%
“…Future work shall focus on tuning the NFC potentiostat to match its recording range to output signals from samples of clinically low analyte concentration. Whilst there is preliminary evidence showing stability over storage of every active component of the device (the electrode, 41 the N protein modified NCM 37 and the detection antibody reagent pad 40 ), a stability study of the complete device was not conducted yet and would be necessary for the device to access the POC market. Lastly, further developments are needed to increase the reproducibility of our measurements.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations