2006
DOI: 10.1118/1.2244633
|View full text |Cite
|
Sign up to set email alerts
|

Po‐Thur Eve General‐06: Experimental Validation of the Eclipse AAA Algorithm

Abstract: The Medical Physics departments of the Tom Baker Cancer Center (TBCC) and the Cross Cancer Institute (CCI) independently performed preliminary evaluation of the new Analytical Anisotropic Algorithm (AAA) implemented in Varian's Eclispe (v. 6.0) treatment planning system (TPS). The TPS was pre‐commissioned with “Golden Beam Data” from the vendor. We measured central and off‐axis profiles in several beam configurations including: open square, rectangular and asymmetric (half‐blocked) beams; wedged square and hal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Numerous previous studies have demonstrated that the Eclipse AAA accurately calculates the dose inside the treatment field and within the penumbra region in both water and heterogeneous media (Aspradakis et al 2003, Sievinen et al 2005, Fogliata et al 2006, 2008, Huyskens et al 2006, Murray et al 2006, Van Esch et al 2006, Breitman et al 2007, Tillikainen et al 2008). In general, the inaccuracies reported in this study are for low dose regions at large distances outside the irradiation target and are of modest significance when considering acute toxicities.…”
Section: Discussionmentioning
confidence: 99%
“…Numerous previous studies have demonstrated that the Eclipse AAA accurately calculates the dose inside the treatment field and within the penumbra region in both water and heterogeneous media (Aspradakis et al 2003, Sievinen et al 2005, Fogliata et al 2006, 2008, Huyskens et al 2006, Murray et al 2006, Van Esch et al 2006, Breitman et al 2007, Tillikainen et al 2008). In general, the inaccuracies reported in this study are for low dose regions at large distances outside the irradiation target and are of modest significance when considering acute toxicities.…”
Section: Discussionmentioning
confidence: 99%
“…All clinical plans were optimized using Varian's Eclipse treatment planning system by an experienced dose planner, and clinical dose maps were calculated using the AAA algorithm. 29 We utilized CERR's QIB algorithm 30 for dose calculation, because it was not possible to obtain the pertinent dose deposition matrices from Eclipse. As such, algorithmic dissimilarity between Eclipse AAA and CERR QIB was a potential issue.…”
Section: Iie Clinical Plan Conversion To Cerr Frameworkmentioning
confidence: 99%