2006 IEEE PES Power Systems Conference and Exposition 2006
DOI: 10.1109/psce.2006.296288
|View full text |Cite
|
Sign up to set email alerts
|

PMU-Based Vulnerability Assessment Using Wide- Area Severity Indices and Tracking Modal Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(14 citation statements)
references
References 10 publications
0
13
0
1
Order By: Relevance
“…In fact, denoting by the th component of the AM-FM signal in (1) and assuming a constant initial phase , it is proven that [12], [13] (4) with a negligible approximation error under quite general and realistic conditions. This motivated the energy separation algorithm (ESA) for tracking the instantaneous amplitude and frequency as follows [13], [14]: (5) Note that, in the case of a monochromatic signal with constant and , the relationships (5) are exact. When the continuous energy operator (3) is sampled with a sampling period T, the following equivalent discrete energy operator is obtained [13]: (6) It results in (7) …”
Section: Overview Of the Teager-kaiser's Energy Operatormentioning
confidence: 99%
See 1 more Smart Citation
“…In fact, denoting by the th component of the AM-FM signal in (1) and assuming a constant initial phase , it is proven that [12], [13] (4) with a negligible approximation error under quite general and realistic conditions. This motivated the energy separation algorithm (ESA) for tracking the instantaneous amplitude and frequency as follows [13], [14]: (5) Note that, in the case of a monochromatic signal with constant and , the relationships (5) are exact. When the continuous energy operator (3) is sampled with a sampling period T, the following equivalent discrete energy operator is obtained [13]: (6) It results in (7) …”
Section: Overview Of the Teager-kaiser's Energy Operatormentioning
confidence: 99%
“…O SCILLATION monitoring [1]- [5] is a topic of increasing recent attention, owing to a heightened interest in the prevention of widespread blackouts, which can result from uncontrolled power swings across large geographical areas. Basically, the entity responsible for this task should first determine from power system response signals when/if there is an oscillation issue and then quantify the underlying threat by means of an accurate assessment of the frequency and damping of the oscillation.…”
Section: Introductionmentioning
confidence: 99%
“…A logic-based method to identify a contingency severity and to assess voltage stability from PMU data is proposed in [15]. A vulnerability assessment method for quickly assessing the post-contingency status of a multi-area power system, using PMU data and Wide Area Severity Indices (WASI), is developed in [16]. These WASI are calculated in the frequency domain through applying the Short-Time-Fourier-Transform (STFT).…”
Section: Pmu-based Vulnerability Assessmentmentioning
confidence: 99%
“…In this aim, a post-contingency VA method for quickly assessing the multi-area vulnerability status is developed in [4]. This method uses PMU data to compute Wide Area Severity Indices (WASI).…”
Section: Introductionmentioning
confidence: 99%