2020
DOI: 10.1016/j.jcis.2019.12.096
|View full text |Cite
|
Sign up to set email alerts
|

Pluronic F127 thermosensitive injectable smart hydrogels for controlled drug delivery system development

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

13
97
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 176 publications
(126 citation statements)
references
References 29 publications
13
97
0
Order By: Relevance
“…for Pluronic® F127 are in a good agreement with previously reported values for similar systems. [50][51][52][53][54] As previously stated, the gelation process is scarcely endothermic (i.e. almost athermal), and thus it has only been observed as a spike on the main peak at concentrations higher than the ones in the present study.…”
Section: Design and Thermal Properties In-house Synthesised Polymersupporting
confidence: 61%
See 3 more Smart Citations
“…for Pluronic® F127 are in a good agreement with previously reported values for similar systems. [50][51][52][53][54] As previously stated, the gelation process is scarcely endothermic (i.e. almost athermal), and thus it has only been observed as a spike on the main peak at concentrations higher than the ones in the present study.…”
Section: Design and Thermal Properties In-house Synthesised Polymersupporting
confidence: 61%
“…1c), is of main importance. As extensively reported in the literature, [47][48][49][50] and shown in Fig. 1c) (left panel), the C gel of Pluronic® F127 is 15 w/w%, and it forms gels at room temperature at 20 w/w% and 25 w/w%, which makes handling of the samples challenging, as previously discussed.…”
Section: Design and Thermal Properties In-house Synthesised Polymersupporting
confidence: 56%
See 2 more Smart Citations
“…Recently, highly tough hydrogels from PNIPAAm and alginate composites whose surfaces were modified by chitosan and carbodiimide crosslinker for adhesive and contacting via body temperature which accelerate wound healing in-vivo in mice has been reported. Another example of thermosensitive hydrogels are Pluronics are polyethylene oxide-based triblock copolymers, known for their bioadhesion, stability and thermosensitive gel forming capability at 30 • C, and are commonly used for injectable drug delivery systems [15]. In addition, polyurethane based hydrogels constituted by poly(glycerol-sebacate) and poly(ethylene-glycol) having thermo-reversibility between 5 and 37 • C has been reported.…”
Section: Introductionmentioning
confidence: 99%