2008
DOI: 10.1016/j.chemgeo.2007.11.005
|View full text |Cite
|
Sign up to set email alerts
|

Plešovice zircon — A new natural reference material for U–Pb and Hf isotopic microanalysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

186
1,348
4
59

Year Published

2014
2014
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 4,274 publications
(1,597 citation statements)
references
References 63 publications
186
1,348
4
59
Order By: Relevance
“…Raw data were reduced using the Iolite software package 64 . Isobaric interferences of 176 Yb and 176 Lu on 176 Hf were assessed and corrected following the procedure described by Woodhead et al 65 Plesovice zircon standard 66 was analysed to correct for instrumental drift, whereas Temora-2 and 91500 zircon references 67 Table 8). On the basis of the results for standards (this session and long term), analytical reproducibility (external precision) for 176 Hf/ 177 Hf is B ± 0.000050 (2 s.d.…”
Section: Methodsmentioning
confidence: 99%
“…Raw data were reduced using the Iolite software package 64 . Isobaric interferences of 176 Yb and 176 Lu on 176 Hf were assessed and corrected following the procedure described by Woodhead et al 65 Plesovice zircon standard 66 was analysed to correct for instrumental drift, whereas Temora-2 and 91500 zircon references 67 Table 8). On the basis of the results for standards (this session and long term), analytical reproducibility (external precision) for 176 Hf/ 177 Hf is B ± 0.000050 (2 s.d.…”
Section: Methodsmentioning
confidence: 99%
“…The reference zircon M127 (Klotzli et al 2009) was used as primary standard. For complementary quality control, a secondary standard was adopted using the Plešovice reference zircon (Slama et al 2008). Additional detailed methodology can be found in Chemale et al (2012).…”
Section: Methodsmentioning
confidence: 99%
“…These data were corrected for the background signal, common Pb, laser-induced elemental fractionation, instrumental mass discrimination and time-dependent elemental fractionation of Pb/U by using an MS Excel spreadsheet program (Gerdes & Zeh 2006). We used the GJ-1 zircon (608 ± 1 Ma, Jackson et al 2004) as the primary reference material and the Plešovice zircon (337 ± 1 Ma, Sláma et al 2008) as a secondary standard for quality control. The signal data were reduced by using the Glitter software (van Achterbergh et al 2001), and age-distribution diagrams were constructed by using Excel Isoplot program (Ludwig 2003).…”
Section: Methodsmentioning
confidence: 99%