Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
BACKGROUND Acromioclavicular joint (ACJ) space narrowing has been considered to be an important diagnostic image parameter of ACJ osteoarthritis (ACJO). However, the morphology of the ACJ space is irregular because of osteophyte formation, subchondral irregularity, capsular distention, sclerosis, and erosion. Therefore, we created the ACJ cross-sectional area (ACJCSA) as a new diagnostic image parameter to assess the irregular morphologic changes of the ACJ. AIM To hypothesize that the ACJCSA is a new diagnostic image parameter for ACJO. METHODS ACJ samples were obtained from 35 patients with ACJO and 30 healthy individuals who underwent shoulder magnetic resonance (S-MR) imaging that revealed no evidence of ACJO. Oblique coronal, T2-weighted, fat-suppressed S-MR images were acquired at the ACJ level from the two groups. We measured the ACJCSA and the ACJ space width (ACJSW) at the ACJ on the S-MR images using our imaging analysis program. The ACJCSA was measured as the cross-sectional area of the ACJ. The ACJSW was measured as the narrowest point between the acromion and the clavicle. RESULTS The average ACJCSA was 39.88 ± 10.60 mm 2 in the normal group and 18.80 ± 5.13 mm 2 in the ACJO group. The mean ACJSW was 3.51 ± 0.58 mm in the normal group and 2.02 ± 0.48 mm in the ACJO group. ACJO individuals had significantly lower ACJCSA and ACJSW than the healthy individuals. Receiver operating characteristic curve analyses demonstrated that the most suitable ACJCSA cutoff score was 26.14 mm 2 , with 91.4% sensitivity and 90.0% specificity. CONCLUSION The optimal ACJSW cutoff score was 2.37 mm, with 88.6% sensitivity and 96.7% specificity. Even though both the ACJCSA and ACJSW were significantly associated with ACJO, the ACJCSA was a more sensitive diagnostic image parameter.
BACKGROUND Acromioclavicular joint (ACJ) space narrowing has been considered to be an important diagnostic image parameter of ACJ osteoarthritis (ACJO). However, the morphology of the ACJ space is irregular because of osteophyte formation, subchondral irregularity, capsular distention, sclerosis, and erosion. Therefore, we created the ACJ cross-sectional area (ACJCSA) as a new diagnostic image parameter to assess the irregular morphologic changes of the ACJ. AIM To hypothesize that the ACJCSA is a new diagnostic image parameter for ACJO. METHODS ACJ samples were obtained from 35 patients with ACJO and 30 healthy individuals who underwent shoulder magnetic resonance (S-MR) imaging that revealed no evidence of ACJO. Oblique coronal, T2-weighted, fat-suppressed S-MR images were acquired at the ACJ level from the two groups. We measured the ACJCSA and the ACJ space width (ACJSW) at the ACJ on the S-MR images using our imaging analysis program. The ACJCSA was measured as the cross-sectional area of the ACJ. The ACJSW was measured as the narrowest point between the acromion and the clavicle. RESULTS The average ACJCSA was 39.88 ± 10.60 mm 2 in the normal group and 18.80 ± 5.13 mm 2 in the ACJO group. The mean ACJSW was 3.51 ± 0.58 mm in the normal group and 2.02 ± 0.48 mm in the ACJO group. ACJO individuals had significantly lower ACJCSA and ACJSW than the healthy individuals. Receiver operating characteristic curve analyses demonstrated that the most suitable ACJCSA cutoff score was 26.14 mm 2 , with 91.4% sensitivity and 90.0% specificity. CONCLUSION The optimal ACJSW cutoff score was 2.37 mm, with 88.6% sensitivity and 96.7% specificity. Even though both the ACJCSA and ACJSW were significantly associated with ACJO, the ACJCSA was a more sensitive diagnostic image parameter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.