2020
DOI: 10.1016/j.talanta.2019.120643
|View full text |Cite
|
Sign up to set email alerts
|

Platform with biomimetic electrochemical sensors for adiponectin and leptin detection in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 29 publications
0
9
1
Order By: Relevance
“…Ince et al presented a sensitive immunosensor system for adiponectin detection (25–2500 pg mL –1 ) . The detection range for adiponectin in our study is also wider than that of the biosensing system reported by Ince et al The proposed GP-based biosensor also showed a lower detection limit compared to the reported studies , given in Table . Moreover, the constructed GP-based biosensor could be prepared more easily compared to that reported by Lee et al As clearly seen in Table , the GP-based biosensor has advantages such as easy preparation, low cost, and ultrahigh sensitivity compared to the other studies.…”
Section: Resultscontrasting
confidence: 40%
See 1 more Smart Citation
“…Ince et al presented a sensitive immunosensor system for adiponectin detection (25–2500 pg mL –1 ) . The detection range for adiponectin in our study is also wider than that of the biosensing system reported by Ince et al The proposed GP-based biosensor also showed a lower detection limit compared to the reported studies , given in Table . Moreover, the constructed GP-based biosensor could be prepared more easily compared to that reported by Lee et al As clearly seen in Table , the GP-based biosensor has advantages such as easy preparation, low cost, and ultrahigh sensitivity compared to the other studies.…”
Section: Resultscontrasting
confidence: 40%
“…It is an anti-inflammatory adipokine and plays a crucial role in glucose and lipid metabolism. All of these relationships have suggested that adiponectin is a possible biomarker of the metabolic syndrome. , Adiponectin, a member of the adipokine family, is involved in many important biological events . It was first recognized that adiponectin is a dysregulated adipose tissue peptide in obesity.…”
Section: Introductionmentioning
confidence: 99%
“…Molecularly imprinted electrochemical sensors are a type of MIP that synergistically combines the advantages of MIP (in particular their selectivity) with those of electrochemical sensors, such as high sensitivity, simple operation, portability, low cost, user friendliness, and fast analysis. , The molecular imprinted electrochemical sensors based on graphene, nanocomposites, carbon nanotubes, and carbon nitride nanotubes , have been intensely used for analysis in last years. In terms of research over the past few years, efforts have been focused on the development of molecularly imprinted electrochemical sensors based on the synthesis of polymers with a predetermined selectivity for a particular target substance …”
Section: Introductionmentioning
confidence: 99%
“…Contrarily to detection approaches commonly proposed by Scheller and his collaborators, here, imprinted polyscopoletin is applied to impedimetric detection. Only very recently, a work proposing an impedimetric sensor based on imprinted polyscopoletin has appeared in literature [78]. Obtained impedimetric data are not rigorously treated and are not characterized by the expected semicircle feature, thus leaving unclear the way for estimating the resistance value to be used as analytical signal.…”
Section: Introductionmentioning
confidence: 99%