2014
DOI: 10.1109/tmtt.2014.2325793
|View full text |Cite
|
Sign up to set email alerts
|

Platelet Orthomode Transducer for <formula formulatype="inline"> <tex Notation="TeX">$Q$</tex></formula>-Band Correlation Polarimeter Clusters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…These will contaminate polarization measurements only through any leakage from total intensity to polarization that could be present in our receivers and that will be caused mainly by asymmetries in the polarizer-OMT system. Considering that our current estimates from OMT laboratory measurements [46] indicate a leakage of the order of ∼ 0.01% this effect is likely to be negligible. We are currently working on a simulation framework that will model the expected fluctuations in the atmosphere brightness temperature and their effect of the sky polarization measurement and will allow us to quantify the impact of this systematic effect.…”
Section: Lspe-strip Noise Estimationmentioning
confidence: 77%
See 1 more Smart Citation
“…These will contaminate polarization measurements only through any leakage from total intensity to polarization that could be present in our receivers and that will be caused mainly by asymmetries in the polarizer-OMT system. Considering that our current estimates from OMT laboratory measurements [46] indicate a leakage of the order of ∼ 0.01% this effect is likely to be negligible. We are currently working on a simulation framework that will model the expected fluctuations in the atmosphere brightness temperature and their effect of the sky polarization measurement and will allow us to quantify the impact of this systematic effect.…”
Section: Lspe-strip Noise Estimationmentioning
confidence: 77%
“…In Q-band we convert linear to circular polarization using a groove polarizer [45] connected to a platelet OMT [46]. In figure 8 we show the complete set of Q-band polarizers (left panel) and OMTs (right panel) implemented in the Strip focal plane.…”
Section: Instrument and Cryogenicsmentioning
confidence: 99%
“…Each array element in the focal plane [16] includes a corrugated feed horn, followed by a dual-circular polarization chain (a groove polarizer [17,18] coupled to an orthomode transducer [19] in the Q-band; and a septum polarizer in the W-band), feeding the polarimetric module based on High Electron Mobility Transistor low noise amplifiers. The signal is then amplified and digitized in the warm electronics unit on board the telescope structure.…”
Section: The Focal Plane Arraysmentioning
confidence: 99%
“…Since the latter directions are rotated by 45 • w.r.t. the inductive (L // x) and capacitive (C // ŷ) principal directions of the polarizer [5], the platelet Ortho-Mode Transducer (OMT) described in [6] is rotated by 45 • w.r.t. the principal axes L and C of the polarizer.…”
Section: The Lspe-strip Instrumentmentioning
confidence: 99%