2018
DOI: 10.1002/mop.31524
|View full text |Cite
|
Sign up to set email alerts
|

Plastic optical fiber respiration sensor based on in‐fiber microholes

Abstract: This paper presents a novel respiration sensor based on multiple in‐fiber microholes drilled along a plastic optical fiber (POF) that is stitched to a waist‐band wrapped around the patient's abdomen. The bending loss of a POF with a single microhole is analyzed in order to enhance the sensor sensitivity. Several sensors were fabricated using a 1.5 mm‐diameter POF with different numbers and spacing of 0.7 mm‐diameter microholes. The sensitivity of the respiration sensor increased when increasing the number and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 16 publications
(26 reference statements)
0
4
0
Order By: Relevance
“…First, a rectangular hole was formed in the POF using an inexpensive drilling machine (SMC HD-280) and a micro-drill bit (NEO Technical System). (21) Subsequently, silver paste was applied on both sides of a small-sized PDLC film for preparing electrodes. Then, two copper meshes were bonded on the silver paste area on both sides of the PDLC film using epoxy.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…First, a rectangular hole was formed in the POF using an inexpensive drilling machine (SMC HD-280) and a micro-drill bit (NEO Technical System). (21) Subsequently, silver paste was applied on both sides of a small-sized PDLC film for preparing electrodes. Then, two copper meshes were bonded on the silver paste area on both sides of the PDLC film using epoxy.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…For better sensitivity and linearity of traditional MBF sensors, recent studies suggest that they can be combined with CRFs, such as U-shaped POFs or D-shaped POFs . Some studies used the methods of punching multiple microholes in the POF or connecting POFs with a silicon tube, of which the essence is to further enhance the optical power attenuation of the MBF. Therefore, such schemes require a trade-off between sensitivity and reliability, avoiding high sensitivity with poor service life.…”
Section: Pulmonary Functionmentioning
confidence: 99%
“…Other researchers show good characteristics for the plastic optical fiber of respiration sensor with the Fiber Bragg Grating (FBG) system placed on the back [8] and also in the breast costume (textile) embedded with a sinusoidal configuration [9]. All reported studies show complicated fabrication, high cost, and low output voltage range [2,[7][8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%