2018
DOI: 10.1080/13632469.2018.1453419
|View full text |Cite
|
Sign up to set email alerts
|

Plastic Hinge Length for Lightly Reinforced C-Shaped Concrete Walls

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 28 publications
0
9
0
Order By: Relevance
“…The authors have derived several expressions for finding the Δ y of lightly reinforced and unconfined rectangular and C-shaped walls (Hoult et al 2018a). Furthermore, several plastic hinge length ( L p ) expressions have been derived from numerical analyses specifically for lightly reinforced and unconfined rectangular and C-shaped walls (Hoult et al 2017a, 2018b). For the sake of brevity, the reader is referred to the “summary of recommended expressions” in Hoult et al (2018a, p. 4855) for all of the PHA equations used to find the displacement capacities of the RC walls used in this study.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The authors have derived several expressions for finding the Δ y of lightly reinforced and unconfined rectangular and C-shaped walls (Hoult et al 2018a). Furthermore, several plastic hinge length ( L p ) expressions have been derived from numerical analyses specifically for lightly reinforced and unconfined rectangular and C-shaped walls (Hoult et al 2017a, 2018b). For the sake of brevity, the reader is referred to the “summary of recommended expressions” in Hoult et al (2018a, p. 4855) for all of the PHA equations used to find the displacement capacities of the RC walls used in this study.…”
Section: Methodsmentioning
confidence: 99%
“…The dimensions of the C-shaped walls for Building Types 2, 3, and 4 in Figure 3 are based on the number of stories; the different building types and ranges of allowable stories (n) used in the program were given in Table 1. Moreover, the dimensions of the C-shaped walls used in the LR, MR, and HR buildings correspond to those used for the numerical analyses conducted in Hoult et al (2018b; dimensions given in Table 3).…”
Section: Building Variabilitymentioning
confidence: 99%
“…The data and information collected from these tests, which is made publicly available (see Section 6, Numerical Data and Reproducibility), will also be beneficial for calibration of finite element models of unconfined RC U-shaped walls with a single layer of vertical reinforcement. (Hoult et al, 2018b;Hoult, 2019). A model of the TUE and TUF specimens in VecTor3 estimated that at a drift of 0.4% for position C, the compressions strains at the flange ends of the U-shaped wall ( Figure 4a) would reach 0.2%.…”
Section: Loading Protocolmentioning
confidence: 99%
“…recording the NS displacements at hNS = 4.25 m (Figure 2b). and allowing secondary cracking to occur (Hoult et al, 2018a;Hoult et al, 2018b;Lu and Henry, 2018).…”
Section: Tue Observationsmentioning
confidence: 99%
See 1 more Smart Citation