2017
DOI: 10.1016/j.surfcoat.2017.02.039
|View full text |Cite
|
Sign up to set email alerts
|

Plasma initiated graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on silicone elastomer surfaces to enhance bio(hemo)compatibility

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…e size of the area is used to determine the effect of collision with the ground, as shown in Figure 5. By adding different types of bounding boxes to the model, different degrees of collision detection can be achieved [33]. When implementing the scene roaming function, the firstperson view object adds the SphereCollider bounding box, which can realize the collision effect with the ground, thereby avoiding "passing through the ground" [34].…”
Section: Analysis Of Virtual Reality Roaming Functionmentioning
confidence: 99%
“…e size of the area is used to determine the effect of collision with the ground, as shown in Figure 5. By adding different types of bounding boxes to the model, different degrees of collision detection can be achieved [33]. When implementing the scene roaming function, the firstperson view object adds the SphereCollider bounding box, which can realize the collision effect with the ground, thereby avoiding "passing through the ground" [34].…”
Section: Analysis Of Virtual Reality Roaming Functionmentioning
confidence: 99%
“…It seemed that the MPC-tethered PEGDMA with a higher P/C ratio (0.071) was more effective for the prevention of bacterial attachment compared to the MPCgrafted PUA with a lower P/C ratio (0.05) (Tables S1 and S2). 32 This result indicates that the antifouling performance could be amplified by integrating the PEGDMA and MPC into the hybrid configuration. Figure 3a-iii shows fluorescence images of E. coli cultured on the PUA and PEGDMA NN array.…”
mentioning
confidence: 95%
“…Bovine serum albumin (BSA) was used to evaluate protein adsorption of each samples. The method described in literature [ 17 ] is as follows: first, PMMA samples were soaked in a phosphate buffer saline (PBS) solution containing 0.2 mg/mL BSA at room temperature for 24 hours. Then each sample was rinsed in pure PBS solution using an orbital table shaker at 150 rpm for 50 minute to remove adsorbed proteins from sample surface.…”
Section: Methodsmentioning
confidence: 99%