2007
DOI: 10.1088/0022-3727/40/12/008
|View full text |Cite
|
Sign up to set email alerts
|

Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives

Abstract: Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (≈1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

5
115
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 157 publications
(120 citation statements)
references
References 16 publications
5
115
0
Order By: Relevance
“…Studies of the fast ion emission from various Plasma--Focus (PF) facilities were performed in many laboratories all over the world, and their results were published in numerous papers which can be found as references in some review papers [1][2][3][4][5]. Such studies have also been carried out within different PF-type facilities in Poland [6][7][8][9][10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…Studies of the fast ion emission from various Plasma--Focus (PF) facilities were performed in many laboratories all over the world, and their results were published in numerous papers which can be found as references in some review papers [1][2][3][4][5]. Such studies have also been carried out within different PF-type facilities in Poland [6][7][8][9][10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…It is known that changing the distance between the anode and the sample (see Fig. 1) allows one to change plasma parameters on the sample surface [16,17] (see also [18,19] for an overview of PF-1000 and [10] for PF-12).…”
Section: Experimental Set-upmentioning
confidence: 99%
“…Thus, the power fl ux density of slow plasma is almost the same for all the samples those were placed at the same distance from the anode. The power fl ux density of slow plasma (E ~ 0.1-1 keV) and fast ions (E ~ 100 keV) was calculated considering initial conditions and plasma properties (velocity of a plasma shock wave and the current rise time) for working PF devices [16,18,19]. The power fl ux density of non-homogeneous slow plasma (E ~ 0.1-1 keV) varied from 5 × 10 7 to 5 × 10 9 W/cm 2 with interaction time equal to 50-100 ns depended on samples' positions.…”
Section: Experimental Set-upmentioning
confidence: 99%
See 1 more Smart Citation
“…Using Lee's analysis, the effect of change in static inductance on ion beam emission has been investigated. Lee's model which is based on the coupling between plasma and current sheath dynamics, as well as plasma thermodynamics, and radiation processes along with device circuit parameters has been extensively and successfully applied to different plasma focus devices from low-to high-energy machines such as UNU/ICTP PFF [12,13], NX1 and NX2 [14], Stuttgart DPF [15], and PF1000 [12,16]. This model assumes that the plasma focus current trace is the fundamental signal from which all of the occurring phenomena can be extracted.…”
mentioning
confidence: 99%