Planar EPID-Based Dosimetry for SRS and SRT Patient-Specific QA

Abstract: The study’s purpose was to develop and validate Electronic Portal Imaging Device (EPID)-based dosimetry for Stereotactic Radiosurgery (SRS) and Stereotactic Radiation Therapy (SRT) patient-specific Quality Assurance (QA). The co-operation between extended Source-to-Imager Distance (SID) to reduce the saturation effect and simplify the EPID-based dosimetry model was used to perform patient-specific QA in SRS and SRT plans. The four parameters were included for converting the image to dose at depth 10 cm; dose-r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 37 publications
0
2
0
Order By: Relevance
“…Several studies have shown that EPID dosimetry is the most convenient tool for rapid and reliable patient-specific QA and can replace detector arrays in performing patient-specific QA of IMRT and VMAT, which can eliminate the need for phantom setup [47][48][49][50][51][52][53][54]. In 2019, Torres-Xirau et al [55] investigated the dose response of EPID in the presence of a magnetic field using Unity MR-linac (Unity, Elekta AB, Stockholm, Sweden).…”
Section: Electronic Portal Imaging Devicementioning
confidence: 99%
“…Several studies have shown that EPID dosimetry is the most convenient tool for rapid and reliable patient-specific QA and can replace detector arrays in performing patient-specific QA of IMRT and VMAT, which can eliminate the need for phantom setup [47][48][49][50][51][52][53][54]. In 2019, Torres-Xirau et al [55] investigated the dose response of EPID in the presence of a magnetic field using Unity MR-linac (Unity, Elekta AB, Stockholm, Sweden).…”
Section: Electronic Portal Imaging Devicementioning
confidence: 99%
“…Popular measurement-based methods for PSQA of lung SBRT plans include film, [7][8][9] multi-dimensional diode arrays, [10][11][12] high-resolution diode arrays, 10,13,14 and electronic portal imaging device (EPID) based QA. 12,[15][16][17][18] Due to the use of small field segments and steep dose gradients that are associated with lung SBRT plans, previous studies have demonstrated the need to use high resolution measurement methods to be able to detect potential errors through the use of stricter gamma criteria. 10,12,17 However, even with high resolution measurement devices, the sensitivity of measurement based QA to detect errors has been shown to be limited.…”
Section: Introductionmentioning
confidence: 99%
“…An electronic portal imaging device (EPID) attached to the linear accelerator (LINAC) has a good resolution and a low volume-averaging effect; moreover, its setup is extremely simple [11][12][13]. Hence, the EPID can overcome the limitations of the array detector [14,15]. Furthermore, several research groups have verified its suitability as a patient-specific QA tool compared to commercial array detectors [13,16,17].…”
Section: Introductionmentioning
confidence: 99%