2012
DOI: 10.1007/978-94-007-5320-4_15
|View full text |Cite
|
Sign up to set email alerts
|

Planar Droplet Sizing for Characterization of Automotive Sprays in Port Fuel Injection Applications Using Commercial Fuel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…The accuracy of SMD measurements from LIF/Mie ratios is also governed by the calibration procedure. The majority of calibration schemes are made using PDA measurements while a few calibration approaches are reported that use a monodisperse droplet generator [38]. Calibration with a monodisperse droplet is preferred because droplets are recorded and evaluated identically to the LIF/Mie ratio scheme (see details in subsection 2B).…”
Section: Introductionmentioning
confidence: 99%
“…The accuracy of SMD measurements from LIF/Mie ratios is also governed by the calibration procedure. The majority of calibration schemes are made using PDA measurements while a few calibration approaches are reported that use a monodisperse droplet generator [38]. Calibration with a monodisperse droplet is preferred because droplets are recorded and evaluated identically to the LIF/Mie ratio scheme (see details in subsection 2B).…”
Section: Introductionmentioning
confidence: 99%
“…LIF/Mie technique can be an attractive alternative to discussed methods as it allows a rapid determination of droplet size distribution across the spray at the same time providing information on global spray parameters, specifically the spray angle. It has been successfully used for port fuel injection studies [10] where injection pressure is very similar to the one in SCR systems. The advantage of this method in reduced measuring times comes along with various challenging issues, such as accuracy limited by multiple-scattering, absorption effects and calibration procedures [10].…”
Section: Introductionmentioning
confidence: 99%
“…It has been successfully used for port fuel injection studies [10] where injection pressure is very similar to the one in SCR systems. The advantage of this method in reduced measuring times comes along with various challenging issues, such as accuracy limited by multiple-scattering, absorption effects and calibration procedures [10]. The calibration procedure is especially difficult for 90 deg detection angle since increase of the scattered light intensity with the droplet diameter is irregular [11].…”
Section: Introductionmentioning
confidence: 99%