2006
DOI: 10.1016/j.ajog.2006.10.195
|View full text |Cite
|
Sign up to set email alerts
|

Placental sharing, birthweight discordance and vascular anastomoses in monochorionic diamniotic twin placentas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
131
0
13

Year Published

2009
2009
2016
2016

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 84 publications
(150 citation statements)
references
References 0 publications
6
131
0
13
Order By: Relevance
“…often seen in nsIUGR twins than in sIUGR twins. Our findings led us to question whether sIUGR and nsIUGR arise from different mechanisms regarding placental angio-structure, the former being related to vascular communication, as described in previous studies, 3,5,14,15 and the latter to placental insufficiency. Also, we wondered if the older maternal age in the nsIUGR-related cases is a predictor of placental insufficiency.…”
Section: Discussionmentioning
confidence: 93%
“…often seen in nsIUGR twins than in sIUGR twins. Our findings led us to question whether sIUGR and nsIUGR arise from different mechanisms regarding placental angio-structure, the former being related to vascular communication, as described in previous studies, 3,5,14,15 and the latter to placental insufficiency. Also, we wondered if the older maternal age in the nsIUGR-related cases is a predictor of placental insufficiency.…”
Section: Discussionmentioning
confidence: 93%
“…MC twins are considered to be at increased risk of adverse outcome compared to DC twins because of vascular anastomoses on the placenta [4][5][6] . Also, in MC pairs, ultrasound examination allows identification of the rare MA twins who are at an even higher risk because of cord entanglement 7 .…”
Section: Discussionmentioning
confidence: 99%
“…Como analizaremos más adelante una de las principales causas es la mala distribución del territorio placentario, pero lamentablemente la ecografía prenatal no puede estimarla. Sin embargo, el sitio de inserción del cordón se puede determinar de forma confiable 9 , y la combinación de una inserción del cordón velamentosa y la otra inserción central puede servir como un marcador de intercambio placentario desigual, y por lo tanto identificar un grupo de gemelos monocoriónicos de alto riesgo para crecimiento discordante 17 .…”
Section: Definicion Y Diagnosticounclassified
“…La asimetría placentaria es a menudo asociada a la inserción del cordón muy excéntrica o velamentosa 16 , aunque no está claro si la inserción velamentosa es una mera consecuencia del desplazamiento asimétrico del ecuador vascular o si tiene alguna implicancia en la fisiopatología. Además de la discordancia del territorio placentario, un segundo factor que influye en gran medida la discordancia de peso fetal y la historia natural de RCIUs en gemelos MC, es la presencia de anastomosis vasculares en el placenta 17,18 , las cuales tienen una fuerte injerencia en la evolución. La cantidad y el tipo de flujo interfetal cambia en función del número y tipo de anastomosis, lo cual determinará una amplia variación en el comportamiento clínico.…”
Section: Etiopatogeniaunclassified