Placement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses

Abstract: BackgroundHigh tibial osteotomy (HTO) with a medially opening wedge has been used to treat osteoarthritic knees. However, the osteotomized tibia becomes a highly unstable structure and necessitates the use of plate and screws to stabilize the medial opening and enhance bone healing. A T-shaped plate (e.g. TomoFix) with locking screws has been extensively used as a stabilizer of the HTO wedge. From the biomechanical viewpoint, however, the different plate sites and support bases of the HTO plate should affect t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(24 citation statements)
references
References 33 publications
1
22
0
1
Order By: Relevance
“…Accordingly, it can be deduced that the configuration (Figure 9) with a higher value of the reaction force (F) is more stable, and the one with a lower pressure (pmax) ensures reduced damage of the bone and, consequently, a higher stability of the implant. To obtain highly reliable numerical models, we set up the FEM models following a largely validated protocol [19,37,39]. Table 3 summarizes the main results obtained for each configuration analysed.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Accordingly, it can be deduced that the configuration (Figure 9) with a higher value of the reaction force (F) is more stable, and the one with a lower pressure (pmax) ensures reduced damage of the bone and, consequently, a higher stability of the implant. To obtain highly reliable numerical models, we set up the FEM models following a largely validated protocol [19,37,39]. Table 3 summarizes the main results obtained for each configuration analysed.…”
Section: Resultsmentioning
confidence: 99%
“…To obtain highly reliable numerical models, we set up the FEM models following a largely validated protocol [19,37,39]. Table 3 summarizes the main results obtained for each configuration analysed.…”
Section: Resultsmentioning
confidence: 99%
“…14,32 Schröter et al 14 reported a screw failure rate of 6% using short spacer plates, and Nelissen et al 32 reported plate breakage in 6.1% of cases and broken screws in 7.5%. Further, Luo et al 33 demonstrated that wedge micro-motion of the anteriorly placed plate was larger than that of the medially placed plate. They also mentioned the potential risk of deterioration of wedge stiffness.…”
Section: Discussionmentioning
confidence: 99%
“…Luo et al reported micromovements of the wedge, 420 μm opening versus 926 μm closing, with a TomoFix plate (Luo et al 2015 ). However, trabecular bone was considered in their model and the axial load that was applied on the tibia plateau was asymmetrical with a distribution of 40% on the lateral side.…”
Section: Discussionmentioning
confidence: 99%