2016
DOI: 10.1016/j.ijheatfluidflow.2016.07.014
|View full text |Cite
|
Sign up to set email alerts
|

PIV measurement and CFD simulation of liquid-liquid flow of a settler in rare earths solvent extraction mixer-settler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…The PIV technology is the latest flow test method, which has been developed by fully utilizing the research achievements of optical technology, image analysis technology, and modern computer technology. PIV is applied to stirred tank, bubble column, hydrocyclone, and flotation column for its unique noncontact and instantaneous measurement advantages. PIV can measure single‐phase flow and two‐phase flow, but it is more mature at present for single‐phase flow test.…”
Section: Methodsmentioning
confidence: 99%
“…The PIV technology is the latest flow test method, which has been developed by fully utilizing the research achievements of optical technology, image analysis technology, and modern computer technology. PIV is applied to stirred tank, bubble column, hydrocyclone, and flotation column for its unique noncontact and instantaneous measurement advantages. PIV can measure single‐phase flow and two‐phase flow, but it is more mature at present for single‐phase flow test.…”
Section: Methodsmentioning
confidence: 99%
“…Mixer-settler is a commonly utilized lanthanides separation device which consists of a mixing chamber bringing convective mixing of immiscible phases and a settling chamber performing phase separation [3]. However, due to the chemical resemblance of lanthanides, it is difficult to achieve their separation thus cascade separation operation with thousands of mixer-settler has to be implemented [1].…”
Section: Nomenclaturementioning
confidence: 99%
“…Grid independence check has been carried out to assure the accuracy of solutions. The total number of meshes is 956017 and the average mesh size is 5.48×10 -7 mm 3 In order to obtain higher processing flux of lanthanide ions, a model with microchannel dimension of 1 mm in diameter was adopted in the following modeling analyses, and the organic to aqueous ratio was kept at 1:1. processes for both La 3+ and Eu 3+ were accelerated by increasing flow velocity. Fig.…”
Section: Numerical Solutionmentioning
confidence: 99%
“…Therefore, mixing time can be directly calculated from the velocity of the mixed fluid [12]. The velocity can be measured by various indirect techniques such as the Laser Doppler Anemometry (LDA) [13,14], Particle Image Velocimetry (PIV) [15,16], or the less common Positron Emission Particle Tracking (PEPT) [17,18]. Furthermore, it can also be calculated with a proper CFD simulator.…”
Section: Introductionmentioning
confidence: 99%