Pitting Corrosion of Some Stainless Steel Alloys Preoxidized at Different Conditions

Abstract: The pitting corrosion of some stainless steel alloys (preoxidized at different conditions) in 3.5% NaCl solution was studied. The alloys are: one ferritic (15.05% Cr) (alloy1) and two austenitic stainless steel alloys (17.9% Cr,7.08% Ni) (alloy2) and (20.45% Cr, 8.3% Ni) (alloy3). Potentiodynamic anodic polarization and galvanic current-time measurements were used in these investigations. The susceptibility of the alloys to pitting corrosion decreases with the increase of chromium content of the alloy and with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2010
2010
2010
2010

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 12 publications
(18 reference statements)
0
2
0
Order By: Relevance
“…This suggests that the inhibition of the stainless steel corrosion in the presence of PVA occurs by adsorption at site on the metal surface. The percentage inhibition efficiency (IE) of PVA inhibitor was calculated according to the following equation: (2) where R 0 p is the polarization resistance in absence of PVA and R p is the polarization resistance in presence of PVA. The values of inhibition efficiency increase with PVA concentration, reaching a maximum value of 73.7% at 3 % PVA concentration, nearly equal to the value obtained from Tafel polarization.…”
Section: Electrochemical Measurements Polarization Curvesmentioning
confidence: 99%
See 1 more Smart Citation
“…This suggests that the inhibition of the stainless steel corrosion in the presence of PVA occurs by adsorption at site on the metal surface. The percentage inhibition efficiency (IE) of PVA inhibitor was calculated according to the following equation: (2) where R 0 p is the polarization resistance in absence of PVA and R p is the polarization resistance in presence of PVA. The values of inhibition efficiency increase with PVA concentration, reaching a maximum value of 73.7% at 3 % PVA concentration, nearly equal to the value obtained from Tafel polarization.…”
Section: Electrochemical Measurements Polarization Curvesmentioning
confidence: 99%
“…304L stainless steel offers good mechanical and corrosion properties, as well as oxidation resistance. Nevertheless, its use is limited due to its susceptibility to some types of local corrosion attack, such as pitting and stress corrosion in the presence of Cl -ions [1,2].…”
Section: Introductionmentioning
confidence: 99%