Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms

Abstract: ObjectiveFlow diversion using the Pipeline embolization device (PED) has become a widely used treatment method for intracranial aneurysms. However, a subset of aneurysms will fail to occlude following treatment and the factors that influence the efficacy of flow diversion remain uncertain. As smaller diameter PEDs inherently have greater metal density than larger devices, we elected to investigate whether PED diameter influences treatment efficacy when using a single device. We also evaluated other factors tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 25 publications
0
9
0
Order By: Relevance
“…7 Some authors found smaller PFS diameter promotes occlusion of small anterior circulation intracranial saccular aneurysms, most likely due to the inherent greater metal density of smaller devices. 1 For distal cerebral artery aneurysms, such as in the MCA, posterior cerebral artery, anterior cerebral artery (A1/A2, pericallosal artery), and the posterior inferior cerebellar artery, PFS use was also associated with good clinical outcome. 17 Twenty procedures were performed on 18 patients, 11 with prior PFS, seven with a vascular reconstruction device, and two previously treated with both.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…7 Some authors found smaller PFS diameter promotes occlusion of small anterior circulation intracranial saccular aneurysms, most likely due to the inherent greater metal density of smaller devices. 1 For distal cerebral artery aneurysms, such as in the MCA, posterior cerebral artery, anterior cerebral artery (A1/A2, pericallosal artery), and the posterior inferior cerebellar artery, PFS use was also associated with good clinical outcome. 17 Twenty procedures were performed on 18 patients, 11 with prior PFS, seven with a vascular reconstruction device, and two previously treated with both.…”
Section: Discussionmentioning
confidence: 99%
“…Patients with complex cerebral aneurysms can now be treated intravascularly with flow-diverting stents as an alternative treatment to coiling with or without stenting. 16 The Medtronic Pipeline flow-diverting stent (PFS; Medtronic, Dublin, Ireland) is the leading braided flow-diverting stent on the market, and this device has had a positive impact on aneurysm repair in the past few years. 4 In a systematic review of early studies (2009–2014), 4 29 studies including 1524 patients with 3 to 62 months of follow-up were analyzed.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, when using FDs in small vessels, it is imperative to understand and consider the effects of oversizing on the FD. Oversizing may result in lengthening of the device, subsequently increasing its porosity and likelihood of aneurysm persistence ( 6 , 7 ). It should be highlighted that in this study, measurements were not made on volume rendering images; rather, they were made on the axial plane after reconstruction of the image using the “Vessel analysis” software.…”
Section: Discussionmentioning
confidence: 99%
“…Flow diversion strategies have gained popularity for cases where coil embolization might be more difficult or likely to fail, such as with large neck side-wall aneurysms, bifurcation aneurysms, or recurrent aneurysms that have already been treated with coil embolization (3)(4)(5). To-date, relatively limited data are available on the feasibility, safety, and effectiveness of flow diversion in aneurysms arising from distal, small-caliber arteries; deploying FDs in such vessels comes with the risk that the FD may become elongated, thus increasing its porosity and lowering the chances of intra-aneurysmal thrombosis (6,7).…”
Section: Introductionmentioning
confidence: 99%
“…Treatments with dual stents of different diameters may result in distinct haemodynamic outcomes, due to the variety of wire configurations following multi-stent implantation ( Shapiro et al, 2014 ; Kole et al, 2019 ; Zhang et al, 2020 ). However, few studies have investigated such variations in stent morphology and the subsequent IA haemodynamics; nor has the correlation between them been established.…”
Section: Introductionmentioning
confidence: 99%