2022
DOI: 10.1007/s00384-022-04178-8
|View full text |Cite
|
Sign up to set email alerts
|

Pilot study of a new freely available computer-aided polyp detection system in clinical practice

Abstract: Purpose Computer-aided polyp detection (CADe) systems for colonoscopy are already presented to increase adenoma detection rate (ADR) in randomized clinical trials. Those commercially available closed systems often do not allow for data collection and algorithm optimization, for example regarding the usage of different endoscopy processors. Here, we present the first clinical experiences of a, for research purposes publicly available, CADe system. Methods W… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 16 publications
(17 reference statements)
0
8
0
1
Order By: Relevance
“…(Supplementary Figure 2). As a new feature of our polyp detection system EndoMind, Poseidon analyzed the images containing a water jet to determine the polyp size [19]. The final size of each polyp was calculated as the average of the determined sizes, but this was not presented to the endoscopists during the experiments.…”
Section: Polyp Sizing In the Silicone-based Colonmentioning
confidence: 99%
See 1 more Smart Citation
“…(Supplementary Figure 2). As a new feature of our polyp detection system EndoMind, Poseidon analyzed the images containing a water jet to determine the polyp size [19]. The final size of each polyp was calculated as the average of the determined sizes, but this was not presented to the endoscopists during the experiments.…”
Section: Polyp Sizing In the Silicone-based Colonmentioning
confidence: 99%
“…bounding box [19]. The second AI algorithm localizes the water jet in the image and determines its diameter.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Lastly, the algorithm was successfully integrated into our previously described real time polyp detection framework [12]. Figure 3 demonstrates the resulting video segmentation and photo-documentation generated after each examination.…”
Section: Real Time Applicationmentioning
confidence: 99%
“…For real-time application, the previously described EndoMind framework [12] was extended with the newly developed algorithm for multilabel classification and consecutive post-processing of the predictions. Real-time prediction is performed at a rate of 10 frames per second.…”
Section: Implementation Of Real-time Applicationmentioning
confidence: 99%
See 1 more Smart Citation