Pilot study: Assessing repeatability of the EcoWalk platform resistive pressure sensors to measure plantar pressure during barefoot standing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 8 publications
0
3
0
2
Order By: Relevance
“…It has been shown that stabilometric parameters measured using pressure platforms provide valid information about postural stability 27 . All the baropodometric variables in this study exhibited lower values in the long term, except for the stabilometric ellipse area, which is possibly Evaluating the effect of a water exercise routine on the postural stability of the elderly due to the fact that a standard position was not established for participants to place their feet on the pressure platform and their base of support could affect said variable 28 .…”
Section: Discussionmentioning
confidence: 78%
See 1 more Smart Citation
“…It has been shown that stabilometric parameters measured using pressure platforms provide valid information about postural stability 27 . All the baropodometric variables in this study exhibited lower values in the long term, except for the stabilometric ellipse area, which is possibly Evaluating the effect of a water exercise routine on the postural stability of the elderly due to the fact that a standard position was not established for participants to place their feet on the pressure platform and their base of support could affect said variable 28 .…”
Section: Discussionmentioning
confidence: 78%
“…Se ha demostrado que los parámetros estabilométricos medidos mediante plataformas de presión proporcionan información válida sobre la estabilidad postural 27 . Todas las variables baropodométricas de este estudio exhibieron valores más bajos a largo plazo, excepto el área de elipse estabilométrica, lo que posiblemente se deba a que no se estableció una posición estándar para que los participantes coloquen sus pies sobre la plataforma de presión haciendo que su base de apoyo afecte dicha variable 28 .…”
Section: Discussionunclassified
“…The sensors activated by each foot provide data for the identification and calculation of baropodometric variables such as body weight distribution and area of the stabilometric ellipse. [ 28 ]…”
Section: Methodsmentioning
confidence: 99%
“…Ecowalk (Ecosanit, Arezzo, Italy), a portable platform composed of 2,304 resistive sensors arranged in an array of 48 X 48 sensors (1 sensor/cm 2 ) and a sample rate of 30 Hz, was used for the kinetic recording. 15 The platform's corresponding data-processing software, EcoFoot 4.0, measured foot pressures and identified their distribution in the dominant leg of the dancer. 9 Each Additionally, a telemetric 8-channel PowerLab16/35 (Adinstrument, Dunedin, New Zealand) was used with an Octal Bio Amp and Labchart 8.0 software to acquire the data of the electric activity of several muscles by means of surface electromyography.…”
Section: Study Of Ballet Dancers During Cou-de-pied Derrière With Dem...mentioning
confidence: 99%