Pilot‐bus selection for secondary voltage control

Abstract: The secondary voltage control determines control device actions based on reference voltage values set at certain load buses denominated pilot buses. A key factor for the appropriate functioning of secondary voltage control schemes is the selection of the pilot buses. This paper addresses this problem taking into account system‐wide information, and different operating conditions regarding different load levels and different network topologies. The proposed approach improves previous approaches in two respects:… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 36 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…Various approaches have been proposed for pilot node selection problem including heuristic methods [2]- [6] and evolutionary optimization-based methods [7], [8]. In [2], the load buses with higher values of short circuit capacity are selected as pilot nodes.…”
Section: B Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Various approaches have been proposed for pilot node selection problem including heuristic methods [2]- [6] and evolutionary optimization-based methods [7], [8]. In [2], the load buses with higher values of short circuit capacity are selected as pilot nodes.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…The generator terminal voltage is taken as control variable. Two different approaches have been proposed to solve the optimization model: heuristic methods [4]- [6] and evolutionary technique [7], [8]. Recently some coordinated secondary voltage control schemes have been proposed to improve voltage stability margin or eliminate voltage violations.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…This system controls the terminal voltage of the generator by Automatic Voltage Regulator (AVR) in the generation level, whereas controls the key bus voltage by control generators in a control regional level. The concept of the key bus and the control area are based on interrelation between a load bus and another load buses by electrical distance [4][5][6][7][8][9]. The on-line voltage control using full SCADA information is implemented in the bulk power system.…”
Section: Introductionmentioning
confidence: 99%
“…Also, the generators should have sufficient capacity of controllable reactive power to master the changes in load voltage magnitudes. The previous proposed methods lie in two main categories: heuristic methods [2][3][4][5][6] and evolutionary optimization-based methods [7]. The heuristics methods are experience based methods that are used to reduce the need for calculations pertaining to problem size.…”
Section: Introductionmentioning
confidence: 99%
“…The most challenging problem in the optimization based method is the solution algorithm. The optimization method, can be solved using heuristic methods [4][5][6] or an evolutionary technique [7]. In the optimization based methods, the independency of pilot nodes (i.e., electrical zones) has not been considered.…”
Section: Introductionmentioning
confidence: 99%