2001
DOI: 10.1002/mrm.1240.abs
|View full text |Cite
|
Sign up to set email alerts
|

Physiological noise in oxygenation‐sensitive magnetic resonance imaging

Abstract: The physiological noise in the resting brain, which arises from fluctuations in metabolic-linked brain physiology and subtle brain pulsations, was investigated in six healthy volunteers using oxygenation-sensitive dual-echo spiral MRI at 3.0 T. In contrast to the system and thermal noise, the physiological noise demonstrates a signal strength dependency and, unique to the metabolic-linked noise, an echo-time dependency. Variations of the MR signal strength by changing the flip angle and echo time allowed separ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

9
161
1
2

Year Published

2006
2006
2015
2015

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 110 publications
(173 citation statements)
references
References 11 publications
9
161
1
2
Order By: Relevance
“…Kruger et al [16] and Triantafyllou et al [17] have shown that physiological noise at high field can cause the timecourse SNR of fMRI series to fall below the image SNR. Because this effect is more pronounced for high fields in combination with large voxel volumes the higher field discourages the use of large voxels.…”
Section: Introductionmentioning
confidence: 99%
“…Kruger et al [16] and Triantafyllou et al [17] have shown that physiological noise at high field can cause the timecourse SNR of fMRI series to fall below the image SNR. Because this effect is more pronounced for high fields in combination with large voxel volumes the higher field discourages the use of large voxels.…”
Section: Introductionmentioning
confidence: 99%
“…If no other effects were to be considered this would lead to a more than quadratic improvement in BOLD effect to noise ratio with field strength [1,2]. However, physiologic noise has T2*-dependent contributions and also increases with field strength resulting in a reduction of the benefit especially if the resolution is kept constant [3]. Bodurka et al [4] have shown that the increased BOLD sensitivity is optimally exploited when the thermal noise together with system instabilities match the physiologic noise.…”
Section: Introductionmentioning
confidence: 99%
“…Zudem ändert sich die transversale Relaxationsrate R2* = 1/T2* für kleine Blutgefäße und Kapillaren quadratisch mit der Magnetfeldstärke, während für grö-ßere Blutgefäße (ableitende Venen) eine lineare Abhängigkeit besteht [18]. Dementsprechend sollten hö-here Feldstärken zu einer höheren Empfindlichkeit gegenüber BOLDÄnderungen vor allem in den Kapillaren führen [19,20], die näher an der zugrundeliegenden neuronalen Aktivierung liegen und bei 1,5T nur sehr kleine Signaländerungen verursachen. Mittlerweile gibt es eine Reihe von Studien, die tatsächlich deutliche Vorteile für die BOLD-fMRT bei höheren Feldstärken zeigen [18,[21][22][23][24].…”
Section: Figures 4a and 4bunclassified
“…durch den Einsatz der parallelen Bildgebung ausgeglichen werden (s. Abbildung 3); allerdings müssen hierbei Effekte durch lokal variierende Rauschverstärkung beachtet werden [27]. Außerdem wird bei höheren Feldstärken das zeitabhängige Rauschen zunehmend von BOLD-artigen physiologischen Fluktuationen dominiert, die von der Signalstärke und der Suszeptibilitätsgewichtung (Echozeit) abhängen [19]. Dadurch sind bei moderaten räumlichen Auflösungen jenseits von 3T kaum noch wesentliche Empfindlichkeitszuwächse zu erwarten.…”
Section: Figures 4a and 4bunclassified