Smith's Textbook of Endourology 2012
DOI: 10.1002/9781444345148.ch49
|View full text |Cite
|
Sign up to set email alerts
|

Physics of Shock‐Wave Lithotripsy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

5
88
1
2

Year Published

2012
2012
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 85 publications
(105 citation statements)
references
References 135 publications
5
88
1
2
Order By: Relevance
“…By varying the distance between the geometrically fixed pulse focus and the skin surface by gel pads of different thickness an adaption to individual soft-tissue conditions of patients can be achieved. Additionally, even thick layers of fat tissue can be overcome without significant attenuation or distortion of the frequency spectrum of the extracorporeal shockwave pulse [28].…”
Section: Discussionmentioning
confidence: 99%
“…By varying the distance between the geometrically fixed pulse focus and the skin surface by gel pads of different thickness an adaption to individual soft-tissue conditions of patients can be achieved. Additionally, even thick layers of fat tissue can be overcome without significant attenuation or distortion of the frequency spectrum of the extracorporeal shockwave pulse [28].…”
Section: Discussionmentioning
confidence: 99%
“…21 The body wall occupies most of this path and because it includes muscle and fat it exhibits greater acoustic absorption than visceral organs such as the kidney. 22 Indeed, the kidney has little effect on SWs as shown by Cleveland and colleagues 15 who compared measures taken with a PVDF membrane hydrophone implanted on the anterior surface versus posterior surface of the kidney in vivo. Of the tissue types along the acoustic path, muscle exhibits the greatest acoustic absorption at the higher frequencies associated with a shock front.…”
Section: Discussionmentioning
confidence: 99%
“…The pressure amplitudes and dimensions of the focal zone are dependent on numerous factors such as the focusing mechanism and the power setting at which the SWs are fired. 1 It is also true that measures of focal width are affected by the type of hydrophone used, and this may account in part for differences in values reported for a given lithotripter. By convention, the focal width is the diameter of the zone (focal zone) spanning the acoustic axis, where the positive pressure is at least half the maximum pressure.…”
Section: Discussionmentioning
confidence: 99%
“…For the most part, the properties of the SWs produced by different lithotripters, regardless of the type of SW generator used (i.e., electrohydraulic, electromagnetic, piezoelectric), are fundamentally the same. 1,2 What distinguishes one lithotripter from the next is its acoustic output, which is described primarily by the magnitude of the acoustic pressures produced and the dimensions of the focal zone.…”
mentioning
confidence: 99%